Flow chart of defrosting start
:
1
、
Select the defrost cycle time according to the table below
Ambient temperature
Low
temperature
( X<21
℃
)
Constant
temperature
(21
℃
≤X<28
℃
)
High
temperature
(28
℃
≤X<35
℃
)
Superhigh
temperature
(35
℃
≤X)
None (open
the door,
thermostat,
special mode
and fault)
40
40
40
14
Door open
14
14
14
14
Overload
14
14
14
14
Others
20
14
14
2
、
Defrosting flow
2
Start
Execute defrosting
N
Y
Y
N
Compressor operate accumulate time
Longer than defrost cycle?
System power on more
than 4 hours?