background image

 

 

                              H-IPRF-16QAM

 

Thor Fiber 2016                    Tel: (800) 521-8467                Email: [email protected]                  http://www.thorbroadcast.com 

 

Chapter 4 Web NMS Management

 

This is literally how you control the device; there is no front interface with D-Pad

 

4.1 Login 

The factory default  IP  address  is  192.168.0.136 and users  can  connect  the  device  and  web  NMS 

through this IP address.   

Connect  the  PC  (Personal  Computer)  and  the  device  with  a  net  cable,  and  use  ping  command  to 

confirm they are on the same network segment. For instance, the PC IP address is 192.168.99.252, 

we then change the device IP to 192.168.99.xxx (xxx can be 0 to 255 except 252 to avoid IP conflict).   

Launch the web browser an input the device IP address in the browser’s address bar and press Enter. 

It will display the Login interface as Figure-1. Input the Username and Password (Both the default 

Username and Password are “admin”. And then click “Login” to start the device setting. 

 

This is the front splash screen with details on your unit – Status & Summary 

 

 

 

Figure-1 

 
 
 
 
 
 

Summary of Contents for H-IPRF-16QAM

Page 1: ...Thor Fiber 2016 Tel 800 521 8467 Email sales thorfiber com http www thorbroadcast com User Manual H IPRF 16QAM Revision 2017...

Page 2: ...part of this document may be reproduced in any form without the written permission of Thor Broadcast The contents of this document are subject to revision without notice due to continued progress in m...

Page 3: ...TION 2 1 5 SPECIFICATIONS 3 CHAPTER 2 APPEARANCE 4 2 1 FRONTAL VIEW 4 2 2 REAR PANEL ILLUSTRATION 4 CHAPTER 3 INSTALLATION GUIDE 5 3 1 IN THE BOX 5 3 2 INSTALLATION PREPARATION 5 3 2 1 DEVICE S INSTAL...

Page 4: ...that supports a maximum 1024 IP TS streams through the 2 GE ports and output 16 or 32 non adjacent carriers 50MHz 960MHz via the single RF output interface on the rear of the unit High performance enc...

Page 5: ...H IPRF 16QAM Thor Fiber 2016 Tel 800 521 8467 Email sales thorfiber com http www thorbroadcast com 1 3 General Mapping 1 4 Carrier Setting Illustration...

Page 6: ...rd ETR289 ETSI 101 197 ETSI 103 197 Connection Local remote connection Modulation Parameters QAM Channel 16 non adjacent carriers Modulation Standard EN300 429 ITU T J 83A B Symbol Rate 5 0 7 0Msps 1k...

Page 7: ...er 2 Appearance 2 1 Frontal View 2 2 Rear Panel Illustration 1 NMS CAS network management port and CA data port 2 RF output port 3 Reset IP Reset webmaster IP address recover to default IP address 4 L...

Page 8: ...ove please contact Thor Broadcast 1 800 521 8467 3 2 Installation Preparation The main steps of the installation include Checking the possible device for missing pieces or damage from transport Prepar...

Page 9: ...07 1X1010 Grounding current limiting resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditioning is recommended Relati...

Page 10: ...oothly General rule of them make sure the device is grounded when installing anywhere Always use copper wire When applied correctly the ground must be wrapped well to ensure maximum conduction so it c...

Page 11: ...h a net cable and use ping command to confirm they are on the same network segment For instance the PC IP address is 192 168 99 252 we then change the device IP to 192 168 99 xxx xxx can be 0 to 255 e...

Page 12: ...e confirm the login it displays the summary interface as Figure 2 Figure 2 4 2 2 Parameters Parameters TS Config Click TS Config it displays the interface where users can configure the output TS param...

Page 13: ...X From the menu on top of the webpage click Output TS X it ll display the interface as in Figure 4 Select the output TS channels Figure 4 Stream Select From the menu on top of the webpage click Strea...

Page 14: ...information Refresh the output program information Select one input program first and click this button to transfer the selected program to the right box to output You can cancel the multiplexed prog...

Page 15: ...ttp www thorbroadcast com Figure 6 General From the menu on the top of the webpage click General it displays the interface where you can set parameters for each output channel Figure 7 Figure 7 Click...

Page 16: ...ass From the menu on the top of the webpage click PID Pass to display the interface where to add the PIDs which need pass through Figure 9 Figure 9 Parameters Scrambler From the menu on left side of t...

Page 17: ...n in Figure 11 where to set RF output parameters Figure 11 This field indicates the current outputting programs The programs selected will be scrambled Scramble channel select carrier select CA channe...

Page 18: ...es thorfiber com http www thorbroadcast com Parameters IP Stream Thor s Edge QAM supports TS to output in IP 16 MPTS format through the DATA port Click IP Stream it will display the interface as shown...

Page 19: ...etwork Click Network it will display the interface as shown in Figure 13 where to set network parameters Figure 13 System Password From the menu on left side of the webpage click Password it will disp...

Page 20: ...e menu on left side of the webpage click Configuration it will display the screen as Figure 15 where to set your configurations for the device Figure 15 System Firmware From the menu on left side of t...

Page 21: ...Email sales thorfiber com http www thorbroadcast com Figure 16 System Log From the menu on left side of the webpage click Log it will display the screen as shown in Figure 17 where to check the Log F...

Page 22: ...aking sure the unit has plenty of ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the AC input within the power supply and ensure it is working the conn...

Page 23: ...00 521 8467 Email sales thorfiber com http www thorbroadcast com Chapter 6 Packing list Thor Broadcast IP QAM Modulator 1 pc User s Manual 1 pc Power Cord 1 pc Thor Fiber Thor Broadcast Los Angeles CA...

Reviews: