37
Connection to the mains
This appliance can only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use
a medium screwdriver. Place it in the 2 slits situated in front of the 2 arrows.
For the various kinds of connection (230V~1P+N or 400V~2P+N), use the brass bridges which
are in the box of connection.
Monophase 230V~1P+N
Put a bridge between terminal L1 and L2.
Put a bridge between terminal N1 and N2.
Attach the earth to the terminate “earth”.
Attach the neutral N to one of the terminals N1 or N2.
Attach the Phase L to one of the terminals L1 or L2.
Biphase 400V~2P+N
Put a bridge between terminal N1 and N2.
Attach the earth to the terminate “earth”,
Attach the neutral N to one of the terminals N1 or N2,
Attach the Phase L1 to the terminals L1
Attach the Phase L2 to the terminal L2.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Ensure that you correctly attach the wires and the bridges and tighten the
screws properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Downloaded from www.vandenborre.be
Summary of Contents for TIH470 FLEXI
Page 1: ...NOTICE D UTILISATION TIH470FLEXI D o w n l o a d e d f r o m w w w v a n d e n b o r r e b e ...
Page 2: ...D o w n l o a d e d f r o m w w w v a n d e n b o r r e b e ...
Page 58: ...D o w n l o a d e d f r o m w w w v a n d e n b o r r e b e ...
Page 59: ...D o w n l o a d e d f r o m w w w v a n d e n b o r r e b e ...