Service manual of MT31AS
The comparison fig of standby power supply
Main IC uses enable control signals such as POWER_ON, LVDS_PWR_EN, BL_EN and MUTE
to control MOS and switch IC to insure Main board work normal. The definition of each enable
signal.
1.POWER_ON
:
Power supply for start up. And control QA05 and U5 to break off after power on.
Supply power for DDR, FLASH and TUNER.
2.LVDS_PWR_EN
:
Power supply for panel enables. Control F04 to supply power for OPEN CELL
singly.
3.BL_EN
:
BL on/off Enable. Control BL driver IC to supply the rise voltage impulse.
4.MUTE
:
Mute function, control UA1
’
s work state.
When POWER_ON is in effect, the input of +5V_NOR can be tested from UA01 and UA02.
The +5V_NOR1 can be tested from UK02. 3.3V work voltage is received by TU1, FLASH and UK03.