BES-6464/75
Rev. 1
9
5.2 Router
mode
The BES-6464/75 router allows switching in different modes. You can choose among:
64x64
AES/EBU 1 Channel
32x32
AES/EBU 2 Channel
21x21
AES/EBU 3 Channel
16x16
AES/EBU 4 Channel
Switches 5 - 6 on the configuration switch SW A set the router’s mode. The Triton Router Control
System software must be configured according to the mode chosen on the router.
The modes can be switched according to the following pattern:
-
means switch down
*
means switch up
Switch
5 6 Mode
- - 64x64
AES/EBU
1
Channel
- * 32x32
AES/EBU
2
Channel
* - 21x21
AES/EBU
3
Channel
* * 16x16
AES/EBU
4
Channel
The printed nomenclature on the BES-6464/75 router is for use with 64x64 AES/EBU 1 Channel. If one
of the other formats shall be used, please connect the AES/EBU signals according to the following tables.
Default mode is 64x64 AES/EBU 1 Channel.
1. AES/EBU 1 Channel
Signal Input
Signal Output
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5
6 6 6 6
7 7 7 7
8 8 8 8
9 9 9 9
10
10
10
10
11
11
11
11
12
12
12
12
13
13
13
13
14
14
14
14
15
15
15
15
16
16
16
16
Summary of Contents for grass valley TRITON
Page 8: ......