20
4. Turn the computer on and start the Chipper Check software. DO NOT try to detect the
chassis at this time!
5. Connect the interface cable to the 212121 adapter board.
6. Connect the adapter board to J13120 (CTC195/197), or J13101 (CTC203) on the
chassis.
7. Connect the interface cable to the interface box.
8. Press the “Detect Chassis” button.
The CTC203 service connector (J13101) is at board location AA-6 near the power switch.
The CTC195/197 (J13120) service connector is at board location KK-6.
Dead Set
1. Remove AC power from the instrument by disconnecting the AC power cord.
2. Click on the “Dead set” button in the main screen.
3. Select the correct TV chassis for the instrument being tested and click on the OK
button.
4. Follow the instructions displayed by Chipper Check software.
Dead set procedures may differ slightly by chassis. It is important to follow the instructions for
the chassis being serviced to ensure proper communication.
Setup MM101, MM102, CTC210, CTC211, and LCOS Chassis
Connecting the Chipper Check interface box to the chassis requires the following:
1. Interface Box
2. Parallel Printer Cable
3. Interface Cable 212118
4. TECI1 Adapter
Things to Consider: