background image

EN

20Nm drive kit 
for rolling shutters and blinds

ref. 500013

45

Kg

3m

www.thomsonbox.eu

v2

Summary of Contents for 500013

Page 1: ...EN 20Nm drive kit for rolling shutters and blinds ref 500013 45Kg 3m www thomsonbox eu v2 ...

Page 2: ... 08 D INSTALLATION 09 1 INSTALLING THE TUBULAR MOTOR 09 2 INSTALLING THE MANAGEMENT MODULE 16 3 CONNECTING THE MANAGEMENT MODULE 16 4 REMOTE CONTROL 17 E CONFIGURATION 18 1 PROGRAMMING 18 2 SETTING MOTOR END STOPS 18 3 PROGRAMMING WITH OTHER ACCESSORIES 19 4 INVERTING RAISING AND LOWERING 19 F USING THE PRODUCT 20 1 USING THE PRODUCT WITH THE REMOTE CONTROL 20 2 USING THE PRODUCT WITH ANY DEVICE 2...

Page 3: ... 7 USING THE GROUP SELECTOR 21 8 REPLACING THE REMOTE CONTROL BATTERY 21 9 MOTOR SAFETY FEATURES 21 G FAQ 22 H TECHNICAL AND LEGAL INFORMATION 23 1 technical characteristics 23 2 warranty 24 3 help and advice 24 4 product returns after sales service 24 5 declaration of conformity 24 ...

Page 4: ......

Page 5: ...replaced by an original part and nothing else Periodically check the installation for any signs of wear or damage to the shutter the mechanical parts and the mounting Do not use the device if repairs or configuration are required 3 RECYCLING Disposing of used batteries in the household waste is strictly forbidden Batteries accumulators containing harmful substances are marked with symbols shown op...

Page 6: ...er tube connector ring 4 Head adaptor 1 End stop configuration button 2 Shutter tube connector ring location 3 Output shaft only driven part in the whole motor 5 Snap ring 6 Pin 7 Management module 8 Remote control 1 x 1 4 x 1 5 x 1 8 x 1 6 x 1 7 x 1 2 x 1 3 x 1 20Nm drive kit for rolling shutters and blinds ...

Page 7: ... Terminal blocks for connecting to the motor and the mains supply 20Nm drive kit for rolling shutters and blinds 4 remote control 2 4 3 5 1 6 7 1 System on indicator light 2 Channel 1 2 3 on buttons 3 Channel 1 2 3 off buttons 4 3 channel on button 5 3 channel off button 6 Group selector 1 2 3 or 4 7 Battery compartment ...

Page 8: ...ighting etc openers shutter motors garage doors etc and manage your energy use heating and electricity consumption with just a few clicks on a computer touchscreen tablet or smartphone from anywhere in the world with an internet connection To enable the above and be able to create scenes action sequences which will simplify your day to day life you need to register your Thombox only when you first...

Page 9: ...9 EN D INSTALLATION 20Nm drive kit for rolling shutters and blinds 1 INSTALLING THE TUBULAR MOTOR Remove the rolling shutter cover ...

Page 10: ...he shutter housing drive plate Remove all obstacles so that there is a flat surface Strengthen if required Note the axis of the axle that the motor will replace then place the motor anchor plate aligning the axis Remove the side plate if required then mark and drill the holes Take care not to damage any components when drilling EN 10 D INSTALLATION 20Nm drive kit for rolling shutters and blinds 58...

Page 11: ...11 EN D INSTALLATION Align the slots on the ring with the motor collar Attach the head adaptor 20Nm drive kit for rolling shutters and blinds ...

Page 12: ... tube must not present any obstacle which prevents the motor being inserted or rotating e g screw attaching the shutter to the tube If necessary remove any obstacles from the tube Insert the motor as far as possible into the tube The ring should be at the far end of the tube i e inserted first ...

Page 13: ...13 EN D INSTALLATION Attach the anchor plate 20Nm drive kit for rolling shutters and blinds ...

Page 14: ... and blinds Ensure that the end stop setting button located at the end of the motor remains accessible Where possible reattach the shutter in an intermediate position neither completely open nor completely shut Attach the anchor plate to the shutter housing ...

Page 15: ...15 EN D INSTALLATION Thread the power supply cable as shown Ensure that it cannot become trapped in any moving parts 20Nm drive kit for rolling shutters and blinds ...

Page 16: ...apped in any moving parts 3 CONNECTING THE MANAGEMENT MODULE WARNING all wiring must take place when the system is isolated circuit breaker set to OFF 3 5 M 3 5 Notes How the raising and lowering phases brown and black wires are assigned is not important as if they are inverted this can be corrected after the wiring is complete The white wire is not used you can cut it off or insulate it with insu...

Page 17: ...17 EN D INSTALLATION 4 REMOTE CONTROL Remove the tab on the back of the remote control to connect the battery 20Nm drive kit for rolling shutters and blinds ...

Page 18: ...s button is difficult to access due to lack of space or proximity to moving parts use a narrow tool to safely press the button To set the end stops you will need to operate the shutter briefly If your shutter is completely open begin by setting the lower end stop If your shutter is completely closed begin by setting the upper end stop If your shutter opens when you ask it to close and vice versa p...

Page 19: ...e time for 3 seconds The LED on the remote control blinks red Then place the device to be controlled into pairing mode Refer to the device s user guide to find out how to do this Note You can pair up to five devices per channel To pair the management module and the motor with another control device refer to the user guide of the device you want to pair with your product During pairing you will be ...

Page 20: ...mote control with a Thombox it does not appear in the dashboard but is available in the rule creator in the Contrôles Controls section You can then create rules which you can trigger using the buttons on your remote control 4 DELETING A DEVICE FROM THE REMOTE CONTROL MEMORY To remove one of the devices controlled using a channel on the remote control repeat the programming steps in this guide with...

Page 21: ... sensor to avoid any damage to the shutter The thermal safety mechanism is designed to prevent the electric shutter motor from damage when the motor is overworked This thermal safety mechanism is triggered if the shutter operates for over 4 minutes or at intervals which are too close together to allow the motor to cool down Wait 10 15 minutes and the shutter will return to normal operation The shu...

Page 22: ...ncorrect wiring The thermal safety mechanism is engaged The force sensor is engaged Check the wiring Wait 15 minutes to give the thermal safety mechanism time to cool down and disengage Identify the blockage and remove it The shutter raises when it should lower Invert raising lowering on the management module Press briefly on the pairing button on the management module The shutter makes a regular ...

Page 23: ...wer Consumption at rated strength Maximum shutter surface Operating temperature Maximum power Assigned operating duration ARW 868 3MHz protocol ARW 868 3MHz protocol Tubular 230V AC motor epicyclic reduction gear assembly Up to 150m in open air Up to 150m in open air 230V AC 50Hz 0 C to 40 C 3V DC via a CR2032 battery 230V AC 50Hz 20Nm 22 4 groups of 3 channels 0 C to 40 C indoor use only 15 rpm 4...

Page 24: ...ill give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may refuse to exchange your product Need help when setting up or installing your Thombox or when pairing your accessories from the Thomson Connected Home range Contact our after sales service technicians on Tel 33 0 892 701 369 Audiotel 0 337 min incl VAT Monday to Friday 9 AM to 12 PM and 2 PM ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...is a TECHNICOLOR S A brand used under licence by Avidsen France S A S 32 rue Augustin Fresnel 37170 Chambray les Tours France ...

Reviews: