Installing Fan to the
Electrical Box
THE OUTLET BOX AND
SUPPORT STRUCTURE MUST
BE SECURELY MOUNTED AND
CAPABLE
OF
RELIABLY
SUPPORTING A MINIMUM OF
50 POUNDS. USE ONLY UL
LISTED
OUTLET
BOXES
MARKED “ACCEPTABLE FOR
FAN SUPPORT OF 22.7 KGS (50
LBS) OR LESS”.
1. Pass the 120-volt supply wires
through the center hole in the ceiling
mounting plate as shown in Fig.11.
2. Install the ceiling mounting plate
on the electrical box by using the mou-
nting screws provided with the electri-
cal box.When using the close-to-ceiling
mounting, it is important that the moun-
ting plate be level. If necessary, use lev-
eling washers(not supplied)between the
mounting plate and electrical box. Note
that the flat side of the mounting plate is
toward the electrical box.(Fig.11)
3. Tighten the two screws on the elec-
trical box securely.
6.
CONNECTING THE SAFETY
CABLE
a. Place the looped end of the safety
cable around the untightened wood
screw as shown in Figure 11a.
b. Tighten the wood screw securing
the safety cable.
CAUTION:
In order to extend the
length of the safety cable, please use
braided steel cable of the same
thickness or greater and secure
according to local and national electric
codes. Please Consult a qualified
electrician if you are in doubt.
4. Carefully lift the fan assembly up to
the ceiling mounting plate and hang the
fan on the hook provided by utilizing
one of the holes at the outer rim of the
ceiling canopy.(Fig.12a,12b)