background image

NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never

expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and

strong vibrations.

NOTICE!
Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches

the voltage rating of the device and that the AC outlet is protected by a residual

current circuit breaker. Failure to do so could result in damage to the device and

possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long

periods of time to reduce the risk of electric shock or fire.

Safety instructions

 

 

active subwoofer

10

Summary of Contents for TP218/1600 A

Page 1: ...TP218 1600 A active subwoofer user manual...

Page 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 02 07 2014 ID 325266...

Page 3: ...tructions 7 3 Features 11 4 Installation 12 4 1 Tips on handling speakers 14 5 Connections and operating elements 15 6 Technical specifications 18 7 Plug and connection assignment 19 8 Protecting the...

Page 4: ...ure that it is available to all persons using this device If you sell the device include the manual for the next owner Our products are subject to a process of continuous development We therefore rese...

Page 5: ...tuation that can result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a pos sible dangerous situation that can result in minor injury if...

Page 6: ...Warning signs Type of danger Warning suspended load Warning danger zone General notes active subwoofer 6...

Page 7: ...cal sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible fo...

Page 8: ...ers There are no user serviceable parts inside DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord Do not modify the mains cable Failure to do...

Page 9: ...n cause hearing damage Decrease the volume level immediately if you experience ringing in your ears or hearing impairment If this is not possible keep a greater distance or use suffi cient ear protect...

Page 10: ...ting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result...

Page 11: ...ial use n Connectivity options powerCON in and output AC IN and AC OUT XLR in and output LINE IN and LINE OUT n 4 pole mount flanges M20 at top side n 12 handles n 18 mm birch plywood housing n Black...

Page 12: ...kaging material suitable for transport or storage respectively Establish all connections as long as the unit is switched off Use the shortest possible high quality cables for all connections WARNING R...

Page 13: ...ns are required for trans port and installation NOTICE Possible property damage by magnetic fields Loudspeakers produce a static magnetic field Therefore maintain an appropriate distance to devices th...

Page 14: ...ods Thus the sound will be evenly spread with maximum range throughout the audience area Always use high grade cable to connect your equipment Otherwise you won t reach max imum sound quality If you n...

Page 15: ...5 Connections and operating elements Connections and operating elements TP218 1600 A 15...

Page 16: ...is looped through from the blue input socket AC INPUT You can use it to feed the power supply to the blue powerCON input sockets AC INPUT of further ele ments 4 LINE IN Line signal input designed as X...

Page 17: ...signal by 180 This avoids unwanted cancellation effects in combination with other speakers 9 LED POWER Power indicator This LED lights up continuously during normal operation and turns off when the su...

Page 18: ...power 4500 W power amp Impedance 4 Sound pressure level 100 dB SPL 136 dB max Frequency response 34 Hz 150 Hz 3 dB Operating supply voltage 230 V AC 50 60 Hz Dimensions W H D 550 mm 1200 mm 680 mm Wei...

Page 19: ...tors one core plus shielding are typical representatives of the unbalanced transmission One conductor is ground and shielding while the signal is trans mitted through the core Unbalanced transmission...

Page 20: ...terfering signal is completely neutralized The result is a pure signal without any noise inter ference 1 Ground shielding 2 Signal in phase 3 Signal out of phase 1 Ground shielding 2 Signal 3 Bridged...

Page 21: ...Please follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste D...

Page 22: ...Notes active subwoofer 22...

Page 23: ......

Page 24: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...