6
Current consumption
The following table contains information on the typical current consumption depending on
the output power level (root mean square value A
RMS
). All values based on a 230 V mains
voltage and a 1 kHz input signal at 0 dB (sine).
Load
1/8 nominal power
1/3 nominal power
8
W
(× 4)
130 W / 1,3 A
190 W / 1,9 A
4
W
(× 4)
180 W / 1,6 A
420 W / 3,1 A
8
W
bridged (× 2)
190 W / 1,6 A
430 W / 3,2 A
Current consumption
digital power amplifier