10 Display.

11

[FUNCTION]

 button

To choose from the various setting options and menu items.

12  button

To increase the displayed value by one.

13  button

To decrease the displayed value by one.

14

[TIMER]

 button

Enters or exits the Timer function.

15

[MANUAL]

 button

Triggers a maximum fog burst as long as the button is pressed.

16

[VOLUME]

 button

Enters or exits the continuous operation with adjustable fog quantity.

Connections and operating elements

 

 

fog machine

22

Summary of Contents for Starville Fire Fogger 1500

Page 1: ...Fire Fogger 1500 fog machine user manual...

Page 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 31 01 2013...

Page 3: ...ion 14 5 Starting up 15 6 Connections and operating elements 17 7 Operating 23 7 1 Remote control functions 25 7 2 Functions in operating mode DMX 27 8 Technical specifications 31 9 Troubleshooting 32...

Page 4: ...ctions Save this manual for future reference Make sure that it is available to all persons using this device If you sell the device to other users be sure that they also receive this manual Our produc...

Page 5: ...symbol and signal word indicates a possible dangerous situation that can result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a possible...

Page 6: ...Warning signs Type of danger Warning high voltage Warning flammable substances Warning hot surface Warning harmful or irritating substances Warning danger zone General notes fog machine 6...

Page 7: ...t physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is respons...

Page 8: ...present Never remove any covers There are no user serviceable parts inside DANGER Electric shock caused by short circuit Do not modify the mains cable or the plug Failure to do so could result in ele...

Page 9: ...ING Risk of burns The generated fog at the fog nozzle is hot and can cause burns Occasionally hot fluid drops may escape from the nozzle The distance of persons and objects to the fog nozzle must be a...

Page 10: ...e floors without a slipping hazard and if necessary remove the condensation WARNING Health hazard caused by fog fluid handling Fog fluid does contain glycols complying with the regulations for foodstu...

Page 11: ...pproved fluids shall be excluded Do not create fog in closed or poorly ventilated areas Do not expose persons with health problems such as allergic respiratory condi tions asthma to artificial fog NOT...

Page 12: ...ecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could resu...

Page 13: ...ne is especially suitable to be used for fire practice Special features of the device n Control via DMX 4 channels or remote control included n Suitable for mobile use n Large fog fluid container Feat...

Page 14: ...ration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Place the device on a level surface T...

Page 15: ...ssible high quality cables for all connections NOTICE Possible data transmission errors For error free operation make use of dedicated DMX cables and do not use ordi nary microphone cables Never conne...

Page 16: ...ther DMX device Connect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is ter...

Page 17: ...6 Connections and operating elements Front panel Connections and operating elements Fire Fogger 1500 17...

Page 18: ...1 Fog nozzle 2 Fluid container with screw cap 3 Carrying handle 4 Fog fluid feed line from fluid container to vaporiser Connections and operating elements fog machine 18...

Page 19: ...Rear panel Connections and operating elements Fire Fogger 1500 19...

Page 20: ...ine from fluid container to vaporiser 5 Connection and storage compartment for the remote control 6 CONTROL OUTPUT DMX output 7 CONTROL INPUT DMX input 8 Main switch to turn the device on or off 9 BAC...

Page 21: ...Remote control Connections and operating elements Fire Fogger 1500 21...

Page 22: ...lue by one 13 button To decrease the displayed value by one 14 TIMER button Enters or exits the Timer function 15 MANUAL button Triggers a maximum fog burst as long as the button is pressed 16 VOLUME...

Page 23: ...listed on www thomann de and follow their instructions for use First make sure the unit is switched off Open the screw cap of the container and fill in the fog fluid Make sure that no fluid is spilled...

Page 24: ...ed operating temperature is reached the display shows Ready To Fog When operating always ensure that there is sufficient fluid in the fog liquid container to avoid no load running Turn off the power u...

Page 25: ...n or continuous operation before you press the button 1 Press FUNCTION repeatedly until the display shows Timer Out Now you can adjust the fog output between 0 and 100 with the arrow keys 2 Press VOLU...

Page 26: ...3 Press FUNCTION repeatedly until the display shows Interval Set Now you can adjust the time intervals between fog bursts in a range between one and 200 seconds with the arrow keys 4 Press TIMER to a...

Page 27: ...13 Fog generation off channels 2 3 and 4 without function 14 127 Continuous operation channel 2 controls output volume channels 3 and 4 without function 128 231 Timer controlled operation channel 2 c...

Page 28: ...tput 100 maximum output volume 3 Fog burst duration in timer controlled operation 0 1 s 5 29 13 s 23 54 33 s 55 79 53 s 80 104 73 s 105 129 92 s 130 154 112 s 155 179 131 s 180 204 151 s 205 229 170 s...

Page 29: ...5 200 s 4 Time interval between 2 fog bursts in timer controlled opera tion 0 1 s 5 29 13 s 23 54 33 s 55 79 53 s 80 104 73 s 105 129 92 s 130 154 112 s 155 179 131 s 180 204 151 s 205 229 170 s Opera...

Page 30: ...Channel Value Function 230 254 190 s 255 200 s Operating fog machine 30...

Page 31: ...Fog output approx 560 m3 min Fluid container capacity 6 l Warm up time approx 10 min Operating supply voltage AC 230 V 50 Hz Fuse 10 A 250 V resettable Dimensions B D H 300 mm 620 mm 210 mm Weight 15...

Page 32: ...9 Troubleshooting In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting fog machine 32...

Page 33: ...n near or alongside to high voltage cables that may cause damage or interference to DMX interface circuits The unit does not eject any fog 1 Check the fluid level in the fog container 2 Check the conn...

Page 34: ...ours or if it was not in use for a longer period of time 1 Make sure that the device is turned off disconnected from the mains and completely cooled down 2 Position the unit in a well ventilated place...

Page 35: ...ontinuous operation and wait until the fog fluid container is empty 7 The cleaning is completed Turn the power off and wait until the unit is fully cooled down before you fill in fog fluid again Clean...

Page 36: ...or recycling Please follow the notes and markings on the packaging This device is subject to the European directive 2002 96 EC Do not dispose of the device with your normal household waste Dispose of...

Page 37: ...Notes Fire Fogger 1500 37...

Page 38: ...Notes fog machine 38...

Page 39: ......

Page 40: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Reviews: