This setting is only relevant if the device is controlled via a DMX controller.
1.
Select the submenu
‘3:DMX’
and confirm with
[Setup]
.
2.
Use
[Up]
|
[Down]
in
‘1)Address’
to assign a DMX address in the range from
‘001’
…
‘512’
to the device.
3.
Use
[Up]
and
[Down]
in
‘2)Channels’
to select one of the following DMX modes.
Mode
Highest possible DMX address
6-channel
507
8-channel
505
12-channel
501
24-channel
489
26-channel
487
28-channel
485
In the sub menu
‘4:Slave’
, use
[Up]
|
[Down]
to choose between
‘Yes’
to enable
or
‘No’
to disable Slave mode.
This setting is only relevant if the device is not controlled via DMX.
1.
Select the submenu
‘5:Dimmer’
and confirm with
[Setup]
.
2.
Use
[Up]
|
[Down]
in
‘1)Red’
to adjust the intensity of the red colour between
‘000’
(off) and
‘255’
(full).
3.
Use
[Up]
|
[Down]
in
‘2)Green’
to adjust the intensity of the green colour
between
‘000’
(off) and
‘255’
(full).
4.
Use
[Up]
|
[Down]
in
‘3)Blue’
to adjust the intensity of the blue colour between
‘000’
(off) and
‘255’
(full).
5.
Use
[Up]
|
[Down]
in
‘4)White’
to adjust the intensity of the white colour
between
‘000’
(off) and
‘255’
(full).
6.
Use
[Up]
|
[Down]
in
‘5)Amber’
to adjust the intensity of the amber colour
between
‘000’
(off) and
‘255’
(full).
7.
Use
[Up]
|
[Down]
in
‘6)UV’
to adjust the intensity of the colour UV between
‘000’
(off) and
‘255’
(full).
A constant colour can only be activated when the unit is operating in stand-alone
mode or as master in a master / slave combination. This setting is only relevant if the
device is not controlled via DMX.
DMX mode
Slave mode
Colour mode
Operating
LED floodlight