Symptom
Remedy
The unit does not work, no light,
the fan does not run
Check the mains power connection and the main fuse.
No response to DMX controller
1. The LED ‘DMX’ should be flashing on data transmis‐
sion. If it doesn't, check the DMX connectors and cables
for proper connection.
2. If the LED ‘DMX’ lights up without response, check the
address settings and DMX polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside
to high voltage cables that may cause damage or inter‐
ference to DMX interface circuits.
If the procedures recommended above do not succeed, please contact our Service Center. You
can find the contact information at
www.thomann.de
.
Troubleshooting
MH-110 Wash 7x10 LED
35
Summary of Contents for STAIRVILLE MH-110 Wash 7x10 LED
Page 1: ...MH 110 Wash 7x10 LED moving head user manual...
Page 4: ...11 Protecting the environment 39 Table of contents moving head 4...
Page 29: ...Overview Operating MH 110 Wash 7x10 LED 29...
Page 40: ...Notes moving head 40...
Page 41: ...Notes MH 110 Wash 7x10 LED 41...
Page 42: ...Notes moving head 42...
Page 43: ......
Page 44: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...