Symptom
Remedy
The unit does not work
Check the mains connection and main fuse.
No haze output
1. Check the fluid level of the hazer fluid.
2. Switch the device off and check the hose that leads into the fluid container
for flow.
3. Check that the quick connector closes completely and sits securely in the
locking system.
No response to the DMX controller
1. Check the address settings and the DMX polarity.
2. Try using another DMX controller.
3. Check whether the DMX cables run near or parallel to high-voltage cables
that may cause damage or interference to a DMX interface circuit.
The display shows the message
‘Beware: No
Liquid!’
1. Disconnect the unit from the power supply.
2. Fill in suitable hazer fluid.
Troubleshooting