background image

 

 

 

2-2 

2. Precautions 

2. 

Precautions on Use 

2-3 

Mounting and Installation

 

  Do not attempt to apply external force on the linear scale, encoder holder or encoder head. 

  Design the assembly with the scale not to have anything that could give influence partially to 

the magnetic field such as metal positioning pins. 

  Avoid any use in an environment with strong external magnetic field such as a place near a 

magnet. 

It may cause a reading error of an encoder or damage on this product. 

Consult with our IOT Innovation Division in case of use in an environment with external 
magnetic field. 

 

  Perform wiring properly following this manual (7-1 Wiring). 

  The users are required to evaluate the performance, safety and EMC by them selves when an 

extension cable other than our standard types is used. Shielded cable is recommended in 

such kind of modification. 

 

  Use protection gears before start working. 

  Make sure there is nobody around you when you transfer a product with long dimension. 

  As a countermeasure for noise from the power supply cable, separate the power supply 

cable from the cables on this product for wiring. 

  Thoroughly remove anti-rust oil and feed lubricant before using the product. 

 

 

2-4 

Operation

 

  Do not operate the product when there is someone in the operation range or in a dangerous 

area. 

  Do not operate the product in a range that exceeds the effective stroke. There is a concern that 

the encoder position data cannot be read. Especially when the product is used as the feedback 
control, the equipment may go out of control, which could cause critical damage, if operation is 

made in a range that exceeds the effective stroke. 

* See this manual (10-2 Effective Stroke) for the effective stroke. 

 

  Ensure safety by means of installation of an appropriate mechanical stopper. 

  Use a device applied with noise countermeasure for the power supply device. 

  Use a higher-level device equipped with power storage feature for a countermeasure of 

power flicker. 

  Set up parameters such as resolution properly. 

Especially when the product is used as the feedback control, the equipment may go out of 
control, which could cause critical damage, if setting of resolution is wrong. 

* See this manual (10-1 Resolution Check) for how to check the resolution. 

  In order to avoid any serious accident in the first operation due to such as wrong wiring, set 

up the torque of the power source low, speed slow and stroke small. 

 

 

 

Caution 

Warning 

Warning 

Summary of Contents for SHS-LE

Page 1: ...Version 1 0 LM Guide with Linear Encoder SHS LE INSTRUCTION MANUAL...

Page 2: ...stallation 2 2 2 4 Operation 2 2 2 5 Lubrication and Maintenance 2 3 3 Marking on the Master Rail and Combined Use 3 1 4 About Product 4 1 4 1 System configuration 4 1 4 2 Product Specifications 4 2 5...

Page 3: ...nd attention Do not use or handle the product in the ways that are not described in this manual Do not reproduce reprint or lend the whole contents or a part of this manual without permission Please n...

Page 4: ...uct is free from failure For applications to the equipment that may suffer serious accidents or loss from the failure of this product install safety devices or backup devices that prevent such serious...

Page 5: ...rd box Fig 2 1 When storing this product please keep it the THK packaging and store it horizontally without subjecting it to high temperatures and or humidity Also do not store it in an environment wh...

Page 6: ...horoughly remove anti rust oil and feed lubricant before using the product 2 4 Operation Do not operate the product when there is someone in the operation range or in a dangerous area Do not operate t...

Page 7: ...s vacuum and low high temperature use the grease appropriate for the specifi cation environment When lubricating the product having no grease nipple or oil hole apply grease directly on the raceway an...

Page 8: ...e 3 Marking on the Master Rail and Combined Use See the Instruction Manual of the LM Guide No 1030 T34667 for Marking on the Master Rail and Combined Use regarding the LM guide Note This product is no...

Page 9: ...directions Fig 4 1 Names of individual parts The LM block is integrated with the encoder holder and encoder head The encoder head reads the positions of N and S magnetic poles recorded in the scales...

Page 10: ...1 3 106 140 57 51 1 8 9 16 8 3 64 4 59 10 4 Block type V LV Fig 4 4 Block type V LV Model No Dimension mm Mass M W L W1 W2 W3 L1 L2 K H3 E e0 LM Block kg LM Rail kg m SHS20V LV 30 44 115 134 20 12 62...

Page 11: ...0 83 0 97 3 2 SHS30R LR 45 60 143 168 28 16 73 3 80 105 50 38 7 12 5 8 1 26 1 58 4 5 SHS35R LR 55 70 162 192 34 18 81 93 123 54 5 47 5 7 5 12 6 5 2 08 2 62 6 2 SHS45R LR 70 86 180 214 45 20 5 94 3 10...

Page 12: ...2012 EN 550112009 AI 2010 EN 610006 2 2005 Use and Storage Ambient Temperature 0 to 50 C No freezing Use and Storage Ambient Humidity 20 to 80 RH No condensation It is the value after multiplying by...

Page 13: ...gives an impact to many conditions such as lubricant condition and payload condition Consult with our IOT Innovation Division for details 4 2 6 General Specifications Temperature Min Max In use 0 to...

Page 14: ...5 Mounting 5 1 5 Mounting 5 Mounting See the Instruction Manual of the LM Guide No 1030 T34667 for mounting...

Page 15: ...6 1 6 Permissible Error 6 Permissible Error of the Mounting Surface See the Instruction Manual of LM Guide No 1030 T34667 for permissible error of the mounting surface...

Page 16: ...next generation model ER04 P8M as the stock ends There should be no change to appearance dimensions pin assignments and communication configurations Make sure to connect the connector hood as it work...

Page 17: ...able Twist Cables should be wired straightly without any twist Fixing or bending of cable while twisted may cause earlier line breakage Fixation of Cable Do not attempt to fix a cable where it moves L...

Page 18: ...use looseness while too short may cause tension at the fixing point This may cause earlier line breakage Adjust a cable to an optimum length when used Fig 7 3 Cable length Cable Wiring In order to avo...

Page 19: ...8 1 8 Lubrication 8 Lubrication See the Instruction Manual of the LM Guide No 1030 T34667 for lubrication...

Page 20: ...kage on a cable Encoder head malfunction Consult with our IOT Innovation Divisions if replacement is necessary Scale malfunction Consult with our IOT Innovation Divisions if replacement is necessary P...

Page 21: ...end is added to the LM block activation range Example 1 For SHS20LE01V 500L because the rail length is 500mm and the block length is 115mm the available activation range should be 500mm 115mm 15mm 15...

Page 22: ...S35LE SHS45LE LM rail standard length Lo 220 220 280 280 570 280 280 360 360 675 340 340 440 440 780 400 400 520 520 885 460 460 600 600 990 520 520 680 680 1095 580 580 760 760 1200 640 640 840 840 1...

Page 23: ...Appendix Revision history The instruction manual No is described on the back cover Date of issue Instruction manual No Details 2 2022 Version 1 0 First edition...

Page 24: ...LM Guide with Linear Encoder SHS LE INSTRUCTION MANUAL 202202 Version 1 0...