SCPI Command Set
:SWEep:ENTRy:DELETE
This commands delete one or all the entries. When an entry is deleted, the following
indexes if existed will be reduced by one accordingly, just as rows in a spreadsheet.
Syntax
:SWEep:ENTRy:DELETE <integer> | ALL
Parameter
<Entry index value> | ALL
Input Data Type
Integer | Character
Allowable Values
1 to COUNt? value
*RST State
N/A
Examples
:SWEEP:ENTR:DELETE 5
:SWE:ENTR:DELETE ALL
:SWEep:ENTRy:NEW
This commands will populate all the capture engine configurations under :SWEep:ENTRy
with default values. No new entry is created until
issued.
Syntax
:SWEep:ENTRy:NEW
Parameter/Response
None
*RST State
N/A
Examples
:SWEEP:ENTRY:NEW
:SWEep:ENTRy:READ?
This query command returns the current configuration settings of a sweep entry.
Syntax
:SWEep:ENTRy:READ? <integer>
Parameter
[Entry index value]
Input Data Type
Integer
Allowable Values
1 to COUNt? value
Query Response
<integer>,<{ingeger | char}>
:==
<RFE mode>,<freq start>,<freq stop>,<freq step>,<freq shift>,
<decimation>, <attenuator>,<IF gain>,<HDR gain>,
<SPPacket>,<packets>,<dwell:second>,<dwell:microsecond>,
<trigger type: NONE |
PULSe | WORD
| <LEVel,freq start,freq stop,
amplitude>
>
Output Data Type
Comma separated integer and character values
*RST State
N/A
Examples
:SWEEP:ENTR:READ? 5
:SWE:ENTR:READ? 1
:SWEep:ENTRy:SAVE
This command saves a new entry into the current editing list with all the current capture
engine configurations under :SWEep:ENTRy. The saving is done by inserting either the
78
ThinkRF WSA5000 Wireless Signal Analyzer Programmer's Guide