background image

Extend    Distribute    Innovate

 

 

REVISION C 

MARCH 2011

 

2.2.  Product Overview 

2.2.1.  Desktop Device 

You may choose to place the chassis on a shelf or desktop (rubber feet included).  The front panel 
should be visible and front panel buttons should be accessible.  All connections are made to the rear of 
the chassis.  The OriginKVM 41 chassis does not need to be opened or accessed.  The sturdy metal 
case allows units to be stacked, as required.

 

 

NOTE:  Be sure to leave adequate ventilation space on both sides of the units 

 

(2” minimum), especially if units are being stacked

.   

2.2.2.  Convection Cooled 

The OriginKVM 41 does not require special cooling or ventilation.  No fans means that it will not add to 
the ambient noise in your equipment room and it is less prone to equipment failure.  Be sure not to block 
the air vents on the sides of the unit.  Leave 

a minimum of 2” clearance on both sides. 

 

 

3.  Connecting the OriginKVM 41 

 

All physical connections to the product use industry-standard connectors.  All connections are found on 
the rear panel of the unit. 

3.1  Front Panel View: LED Indicators 

 

 

 

 
 

Power

  

LED on (green)  

Power is connected and supplied to OriginKVM 41. 

 

 

LED off  

 

Power is not connected and/or not supplied to OriginKVM 41. 

 

Console 

 

1     

LED on (green) 

Port 1 of the USB hub is powered and operational. 

    

LED off 

Port 1 of the USB hub is not functional. 

2     

LED on (green) 

Port 2 of the USB hub is powered and operational. 

 

LED off 

Port 2 of the USB hub is not functional. 

3     

LED on (green) 

Port 3 of the USB hub is powered and operational. 

 

LED off 

Port 3 of the USB hub is not functional. 

4     

LED on (green) 

Port 4 of the USB hub is powered and operational. 

 

LED off 

Port 4 of the USB hub is not functional. 

CPU 1-4 

 

SEL 

LED on (green) 

Channel is selected. 

 

USB 

LED on (green) 

USB is connected properly and power is supplied. 

 

HDMI 

LED on (green) 

HDMI is connected properly and power is supplied. 

 

IR 
 

ACT 

LED on (green) 

IR Receiver is communicating/receiving data from the remote. 

Summary of Contents for OriginKVM 41

Page 1: ...ION C MARCH 2011 OriginKVM 41 Product Manual Extend Distribute Innovate Thinklogical LLC 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 Fax 1 203 783 9949 www thinklogical com ...

Page 2: ... reserved Printed in the U S A Thinklogical a subsidiary of Logical Solutions LLC 100 Washington Street Milford Connecticut U S A 06460 Telephone 1 203 647 8700 All trademarks and service marks are property of their respective owners Subject OriginKVM 41 4x1 KVM Switch Revision Rev C March 2011 ...

Page 3: ...3 3 3 HDMI to DVI 2 Meters CBL000030 002MR Qty 4 7 4 Installation 8 5 Regulatory and Safety Compliance 9 5 1 Safety Requirements 9 5 1 1 Symbols Found on Product 9 5 2 Regulatory Compliance 9 5 2 1 North America 9 5 2 2 Australia New Zealand 9 5 2 3 European Union 9 5 2 3 1 Declaration of Conformity 9 5 2 3 2 Standards with Which Our Products Comply 10 5 2 4 Supplementary Information 10 5 2 5 Prod...

Page 4: ......

Page 5: ... The Thinklogical OriginKVM 41 is a high performance KVM switch that enables one user station to access and switch between four multi platform servers or computers The OriginKVM 41 improves operational productivity from the simplest to the most complex requirements and for applications such as hardware software development testing labs network server management and multi workstation operation Inpu...

Page 6: ...atures Switches DVI HDMI USB and Line Level Audio IR Remote Control optional Select Switches on the front panel 4 port USB hub console USB Power Power from DVI HDMI and Selected Port CPU LED Indicators BIOS level access Plug and play No configured required Internal universal power supply Country specific power cables available upon request Uses standard IEC power cable Supports any mix of computer...

Page 7: ...n 3 2 for more details on the Rear Panel Operating Temperature and Humidity 0 to 50 C 32 to 122 F 5 to 95 RH non condensing Enclosure Dimensions Approx 15 795 x 7 654in x 1 640in high 40 119cm x 19 441cm x 4 166cm high Tolerance 039 100cm Weight 4 lbs 1 81 kg Shipping Weight 16 lbs 7 26 kg Copper Cables supplied with unit 4 3 5mm Male to 3 5mm Male Plug 6FT Thinklogical Part Number CBL000016 006FR...

Page 8: ...on both sides 3 Connecting the OriginKVM 41 All physical connections to the product use industry standard connectors All connections are found on the rear panel of the unit 3 1 Front Panel View LED Indicators Power LED on green Power is connected and supplied to OriginKVM 41 LED off Power is not connected and or not supplied to OriginKVM 41 Console 1 LED on green Port 1 of the USB hub is powered a...

Page 9: ... View CPU 1 IN CPU 2 IN CPU 3 IN CPU 4 IN Console OUTPUTS Power ON OFF 3 3 Cables 3 3 1 3 5mm to 3 5mm Cable 6 Feet CBL000006 006FR Qty 4 3 3 2 USB A B Cable 6 Feet CBL000015 006FR Qty 4 3 3 3 HDMI to DVI 2 Meters CBL000030 002MR Qty 4 USB A USB B HDMI Male DVI Male ...

Page 10: ...ort to the OriginKVM 41 s USB B IN from CPU 1 Port 3 Connect the included 3 5mm to 3 5mm cable CBL000016 006FR from the CPU 1 Audio Output to the OriginKVM 41 s 3 5mm Audio IN from CPU 1 Port 4 Repeat Steps 1 3 for CPUs 2 through 4 Console Connections 1 Connect an AC Power Cord to the OriginKVM 41 and turn the unit ON 2 Plug the DVI Display into the HDMI port labeled HDMI OUT 3 Connect up to 4 USB...

Page 11: ...orth America These products comply with the following standards Safety ANSI UL60950 1 1st Edition 2003 CAN CSA C22 2 No 60950 1 03 Electromagnetic Interference FCC CFR47 Part 15 Class A Industry Canada ICES 003 Issue 2 Revision 1 5 2 2 Australia New Zealand This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take c...

Page 12: ...e FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential ...

Page 13: ...hat the first line of support is the design engineer that developed each product Therefore your questions will be handled promptly by our most knowledgeable engineers Thank you for choosing Thinklogical products for your application We appreciate your business and are dedicated to helping you successfully use our products is always here to help you To contact us please use the following telephone ...

Page 14: ...know the best time to call you back so we may reach you at your convenience Our switchboard attendant will direct your call during regular business hours We have an automated attendant answering our main telephone switchboard after regular business hours and on holidays so you can leave a voice message at any time Our Sales Representatives have direct numbers to better serve you 6 1 4 Fax Our comp...

Page 15: ...contact the Thinklogical authorized dealer from whom you purchased the product Do not return a product directly to Thinklogical without prior authorization from your dealer If you have received prior authorization from your dealer and are returning a product directly to Thinklogical 1 Contact a sales representative or call Customer Support at 1 800 291 3211 or 1 203 647 8700 2 Describe the defect ...

Page 16: ...itor type connect a DVI to HDMI or an HDMI to HDMI Cable between the OriginKVM 41 s HDMI OUT port and your workstation viewing device STEP 3 Connect your Audio and USB workstation devices to the OriginKVM 41 s Output Ports STEP 4 Connect your HDMI USB and Audio OUT Cables from Source CPUs 1 4 to the OriginKVM 41 s CPU1 CPU4 INPUT Ports Ensure that the CPUs are turned ON Verify that all system func...

Page 17: ...rol Protocol OriginKVM 41 Serial Port Control Protocol The OriginKVM 41 is wired as DTE and has a DB9 M connector Byte seq 0 1 2 3 4 5 ASCII string 0 x N CR LF Where x 1 to 4 CR 0x0d LF 0x0a The baud rate is 9600 8 data bits 1 stop bit no parity no flow control PC OriginKVM 41 Pins 2 3 3 2 5 5 ...