![Think Appliances GCE7000 User Manual Download Page 16](http://html.mh-extra.com/html/think-appliances/gce7000/gce7000_user-manual_1107030016.webp)
Electrical connection
This appliance must be installed by a qualified
person in accordance with the latest edition of the
Regulations currently in force and in compliance
with the manufacturer’s instructions.
o
AS/NZS 3000: 2007 Wiring Regulations
o
2010 Electricity Safety Regulations
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
The appliance must be wired into a 30A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. It should
not be located above the appliance and no more than 1.25m
away from it.
o
The spur outlet must still be accessible even when your cooktop
is located in its operating position.
o
Cable type: H05 VVF 3 core x 6 mm²
Connecting the mains supply cable
o
The mains terminal block is located on the
underside of the cooktop and the terminals are
accessible by removing the terminal block cover.
This is done by depressing the front of the cover
and releasing it from the securing clips.
15