THIESEN ACL-Modul Mounting Instruction Download Page 2

I

important notes 

Carefully mount the cables inside the rudder and/or the fuselage. Connect the cables professionally to the aircraft system 

(red = positive, 

)

 and to a 5 Amps fuse protection. Luster terminals are not 

black = negative

yellow = synchronisation

suitable  to  connect  cables. There  is  a  good  selection  of  suitable  crimp  connections  in  various  shops.  If  you  do  not  use 
synchronisation, please isolate the yellow synchronisation cable.

The ACL is provided with overload protection. In case of over voltage the protector switches off the ACL. After reset or voltage 
drop  the ACL  is  again  fully  functional. The  automatic  overload  protector  shall  be  activated  at  a  voltage  above  18  Volts. 
(If the voltage reduces to a value below 18 Volts, the ACL will again be functioning)

Servicing / maintenance

For additional UV protection, use varnish. Should the ACL be scratched, use a good polish to refurbish the damages. With 
slightly  deeper  scratches  use  wet  sandpaper  with  very  fine  granulation  (800-1000)  carefully  polish  again.  Do  not  use 
aggressive chemicals like gasoline or solvent.

For day to day cleaning use soap water!

Some insect removers and detergents forces embrittlement of epoxy based plastics and laminates. Use only aircraft certified 
products.

 If the aircraft can not hangarized, please cover the lamps to prevent surface aging!

Electric power supply / cable connection to the aircraft system (12 Volts)

The ACL-Modul has a 3 pin connecting plug. A suitable connecting cable with plug is enclosed. Alternative a connector casing 
and suitable connector plugs are enclosed.
The best connection is solder with additional shrinking of the soldering joint with a shrink hose (enclosed). Only use solder for 
electronic soldering  never use cored solder. It contains acids which cause corrosion!

Technical data

 

Operating voltage :  10-17 volts (DC), typically 12.8 - 13.4 volts 
Input 

:  approx. 20 watts

Fuse 

:  5 ampere (fusible cut-out or automatic fuse)

Dimensions 

:  165 x 14 x 20 mms 

Drill hole 

:  4.5 mm

Weight 

:  approx. 58 grams with connecting cables

Warranty

 

:

 

5,000 operating hours or max. 3 years

Subject to changes without notice

5.000 hours or max. 3 years

assured luminous duration

Made in Germany

Verdrillte Leitungen / 

twisted cable 

=

Right 
EPTA
EPTA-LSA

+

_

12 Volt Battery

Fuse 5 A

Fuse 5 A

Switch

Switch

ACL3is
ERBis

ACL-Modul

ELL60
ELL50
ETL50

Left 
EPTA
EPTA-LSA

gelb / yellow

Fuse 5 A

Switch

Positionslicht

Landescheinwerfer

Antikollisionslicht

rot / red 

= Plus 12 Volt

schwarz / black  = Minus 12 Volt
gelb / yellow 

= Synchronization-Cable

blau / blue 

= Plus 12 Volt Landescheinwerfer

Im Tiegel 9

36367 Wartenberg 

Germany

Tel.: +49 (0) 66 41 - 979 - 0

eMail: [email protected]

www.thiesen-electronics.com

www.flugzeuglichter.de

THIESEN

E L E C
TRONICS
G M B H

Wiring diagram: