© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021821/08/21
Tel. +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·
Page 64 of 102
7.2.10 Command DS
<id>DS<parameter><CR>
Readout archive
Access:
Reading / writing
Description:
With the command “DS”, the archived measured values
are output in lines separated by semicolon characters.
If no parameter is stated, all archived measured values
are output.
Parameter description:
AAAA BBBBBBBBBBBB EEEEEEEEEEEE
AAAA:
Stating of the archive with 3 and/or 4 digits (“AV1” to “AV16” or
“EX1” to “EX16”)
BBBBBBBBBBBB:
Starting time of the form YYMMDDHHNNSS
(YY: year, MM: month, DD: day, HH: hour, NN: minute, SS:
second)
EEEEEEEEEEEE:
Ending time of the form YYMMDDHHNNSS
(YY: year, MM: month, DD: day, HH: hour, NN: minute, SS:
second)
Value range:
see parameter description
Initial value:
7.2.11 Command DS_ESC
<id>DS_ESC<CR>
Stop readout process for archive
Access:
Reading / writing
Description:
With the command “DS_ESC”, the readout of an archive
(
Command DS) is stopped.
Value range:
Initial value:
7.2.12 Command DD
<id>DD<parameter><CR> Date
Access:
Reading / writing
Description:
With the command “DD”, the current date is read or set.
Parameter description:
YYMMDD
YY:
year
MM:
month
TT:
day
Value range:
Initial value: