![Thies CLIMA 9.2750.00.900 Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/thies-clima/9-2750-00-900/9-2750-00-900_operating-instructions-manual_1106917005.webp)
3 View
Button "DOWN"
Button
"INFO & RESET"
Button "MODE"
Button "UP"
"Dimension"
Min/Max LEDs
4 x 5-digit
LED displays
Button
4 Mode of Operation
4.1 Calculation of sliding mean and extreme values:
To process the sliding measured values two ring buffers with a depth of 60 single values are
available for each measured value. With processing of the measured values every second this
results in a 1-minute sliding extreme and mean value. With the selection of times > 1min, the
measured values are processed to produce an integral extreme and mean value prior to sliding
processing.
Sliding
time
Integral mean from
n values (pre-
averaging)
Sliding mean value
from n
integral values
1 min
1
60
10 min
10
60
1 h
60
60
24h 1440
60
5 - 30