Thies CLIMA 5.4033.35.040 Instructions For Use Manual Download Page 15

 

15 - 18 

021326/05/10

 

 

9 Dimensional 

Drawing 

Description 

MIN 

TYPE 

Max 

Unit 

General 

 

 

 

 

Collecting surface 

 

200 

 

cm

2

Volume of tipping bucket 

 

 

cm

3

Measuring range 

 

11 

mm/min 

Resolution  

0,1 

 

mm 

NS 

Accuracy (within the range of  0.. 11 mm/min) 

 

 

±

 3  * 

%

 

Ambient temperature (w/o heating) 

 

60 

°C 

Ambient temperature (with heating) 

- 25 

 

60 

°C 

Mounting on stand pipe (1 ½“) 

 

 

50 

mm 

Weight  

 

3,3 

kg 

 

 

 

 

 

Electrical Output 

 

 

 

 

Output 1: Analogue 

 

 

 

 

Resolution of analogue value 

 

960 

 

steps 

Accuracy of analogue value 

 

± 1 

 

% of m.r 

Linearity error 

 

 

± 0.1 

Load  (Vcc 

 17V) 

 

 

500 

ohm 

Load (Vcc 

 10V) 

150 

 

 

ohm 

I

max (voltage output 0..10V) Vcc 

 13V 

1     mA 

I

max (voltage output 0..10V) Vcc 

 17V 

 20    mA 

 

 

 

 

 

Output 2: Digital (opto-coupler) 

 

 

 

 

Pulse length 

 

125 

 

ms 

Pulse pause 

125 

 

 

ms 

Tipping bucket frequency 

 

Hz 

Supply voltage 

 

 

24 

V DC 

Pulse current 

16 

 

mA 

Rv (pre-resistance in the precip. transmitter ) (fig.) 

 

100 

 

 

 

 

 

 

 

Reset-input (opto-coupler) 

 

 

 

 

Pulse length 

70 

 

 

ms 

Pulse current 

 

40 

mA 

Rv (pre-resistance in the precip. transmitter) (fig.) 

 

6200 

 

ohm 

 

 

 

 

 

Supply voltage 

 

 

 

 

Vcc  (with heating) 

 

24 

28 

V (AC/DC) 

Vcc (w/o heating) 

10 

 

24 

V (DC) 

Icc  (w/o heating) (at voltage output) 

 

 

mA 

 

 

 

 

 

Heating 

 

 

 

 

Heating power (at 24V supply) 

 

48,5 

 

heating – switch-on temperature 

 

 

°C 

Heating - hysteresis 

 

 

°C 

 

 

Summary of Contents for 5.4033.35.040

Page 1: ...THER DATA Precipitation Transmitter 5 4033 35 xxx 5 4033 36 xxx Instruction for Use 021326 05 10 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 49 55...

Page 2: ...ons The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device...

Page 3: ...ing 10 6 2 1 Plug mounting 10 6 3 Connecting Diagram 11 7 Setting the Signal Processing Measuring Range and gliding Period 11 8 Maintenance 13 8 1 Cleansing Procedure 13 8 2 Check of the Tipping Bucke...

Page 4: ...e and the collecting funnel is conducted into a tipping bucket The tipping bucket consists of two bucket compartments Is one of these compartments filled with water it tips over and the water drains o...

Page 5: ...can reset the analogue value at any time see figure 1 Application example for accumulating precipitation sum for recording the precipitation on recording instruments 2 Gliding Precipitation Sum the su...

Page 6: ...od gliding precipitation sum 5V Figure 2 gliding precipitation sum Updating Time With gliding Period every 25 sec 10 Min every 150 sec 60 Min every 15 min 6 h every hour 24 h Table 2 Updating 4 2 Outp...

Page 7: ...The precipitation gauge is to be installed in such a way that the collection area is horizontal and is situated 1 m above ground If snowfall is to be expected regularly within the area of the measuri...

Page 8: ...the base 3 5 Loosen two screws 2 at the housing 1 and lift the housing carefully up 6 Please check if the level indicator 5 on the ground plate indicates a horizontal mounting if necessary correct it...

Page 9: ...pan 6 tipping bucket 7 filter 12 magnet 10 knurled screw 11 nozzle 9 collector 13 filter 14 cram 15 base 3 screw 4 pc board 8 housing 1 level indicator 5 screw 2 9 18 021326 05 10...

Page 10: ...upling socket Typ Binder Serial 423 EMC with cable clamp Cable connection without cable shield Cable pull relief 1 Stringing parts on cable acc to plan given above 2 Stripping cable sheath 20 mm 3 Cut...

Page 11: ...4 5 6 7 2 3 Erde Earth Reset Impuls Analog 7 Setting the Signal Processing Measuring Range and gliding Period only necessary in case the factory adjustment is to be changed On the pc board there is a...

Page 12: ...N 25 mm CLOSED OPEN ON OFF 50 mm OPEN OPEN OFF OFF Gliding Period DIP switch 3 DIP switch 4 DIP switch 3 DIP switch 10 min CLOSED CLOSED ON ON 60 min OPEN CLOSED OFF ON 6 h CLOSED OPEN ON OFF 24 h OPE...

Page 13: ...of which is specifically oxidised in order to achieve a hygrophile surface It guarantees an accurate draining behaviour of the measuring liquid and must not be removed mechanically The maintenance in...

Page 14: ...mount of precipitation slowly and steadily into the collecting funnel That means that for example a quantity of 200 cm induces a pulse number of 100 The quantity of 200 cm should be filled in constant...

Page 15: ...arity error 0 1 Load Vcc 17V 500 ohm Load Vcc 10V 150 ohm Imax voltage output 0 10V Vcc 13V 1 mA Imax voltage output 0 10V Vcc 17V 20 mA Output 2 Digital opto coupler Pulse length 125 ms Pulse pause 1...

Page 16: ...a 10 Connection Diagram 159 6 350 445 186 50 50 deep 11 Accessories deliverable as options Stand 9 4031 35 065 Serves for mounting the precipitation transmitter The distance from the ground to the col...

Page 17: ...006 95 EC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use wit...

Page 18: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 18 18 02132...

Reviews: