7 Wiring 

diagram 

 

Attention:

  

When the wind vane rotates over the north point (0 / 360°) the 
potentiometer slider connects beginning and end of the 
potentiometer. Therefore, the supply voltage of the potentiometer 
must show a current limitation of max. 1 mA. When using power 
supply units temporary current peaks with the power control might 
lead to damages. Therefore, an additional protective resistance Is 
strongly recommended .  

 

 
Order - no. 
 
4.3120.22.002 
4.3120.22.012 
4.3120.22.018 
4.3120.22.712 

 

  6   7

  4   5

Heating

  20 W

  1   2   3

Hz

Hz

He

at

in

g p

owe

r s

up

ply

 

24

 V

 A

C

 / DC

  20

 W

A a R e E

Poti

Wind direction

8 pole Euchner  plug

 

• 

Using without heating: Pin 6 + 7 not connected.

 

 

7 - 12 

021262/11/07

 

 

Summary of Contents for 4.3120.22 Series

Page 1: ...TA Instruction for Use 021262 11 07 Wind Direction Transmitter with potentiometer output 4 3120 22 xxx ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone...

Page 2: ...ons The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device...

Page 3: ...7 8 Technical Data 8 9 Dimensions 9 10 EC Declaration of Conformity 10 Figure Figure 1 Dimension 4 3120 22 0xx 9 Figure 2 Dimension 4 3120 22 712 9 1 Models Order No Meas range WD Electrical Output Mo...

Page 4: ...3 Construction and Mode of Operation The housing and wind vane are made of aluminum die the surfaces are anodized Labyrinth seals and o rings protect the sensitive internal parts from precipitation Th...

Page 5: ...er No 4 3100 99 000 is recommended if the instrument is to be used in areas with considerable lightning activity 5 1 Mounting the wind vane Unscrew the cap nut SW 8 from the case of the Wind Direction...

Page 6: ...mitter is the roll axis of the ship whereat 0 is related to the ship bow Rotate the case markings north marking on the shaft and on the protective cap until they are aligned Take a bearing on ship bow...

Page 7: ...ion of max 1 mA When using power supply units temporary current peaks with the power control might lead to damages Therefore an additional protective resistance Is strongly recommended Order no 4 3120...

Page 8: ...st guarantee a current limiting to max 1 mA short cut at the North point max 24 V 1 5 W max 24 V 1 5 W The supply must guarantee a current limiting to max 1 mA short cut at the North point Heating 24...

Page 9: ...9 Dimensions 125 425 415 70 50 36 50 Figure 1 Dimension 4 3120 22 0xx 60 300 280 70 50 36 50 Figure 2 Dimension 4 3120 22 712 9 12 021262 11 07...

Page 10: ...States relating to electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 March 2004 on the interop...

Page 11: ...11 12 021262 11 07...

Page 12: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 12 12 02126...

Reviews: