Working with batteries 

Using batteries in a wrong way may result in danger for personnel, animals or the environment. Check information 
from battery manufacturer for safe installation and operation.  

If battery acid contacts skin or clothing, wash immediately with soap and water. If acid contacts eyes, immediately 
flush with running cold water for at least 20 minutes and get medical attention as soon as possible. 

Never smoke or allow a spark or flame in vicinity of batteries. 

Do not drop metal tools on batteries. The resulting spark or short circuit may cause an explosion. 

Remove personal metal items such as rings, bracelets, necklaces and watches when working with batteries. 

13  Planning and mounting the inverter 

This section will provide you information’s about configurin

g and installing your inverter. Make sure that you are 

aware of local rules and safety measurements. 

13.1 

Required power draw 

Before connecting your appliances to the inverter, always check the power draw required. The inverter is afforda-
ble to supply surge power for a short time, so as to start up electrical equipment such as pumps, motors, etc. 
Some equipment needs more power while starting up. 

The inverter is protected against overload and will switch off automatically when overload is applied. As ambient 
temperature is above 20°C the inverters nominal power may be smaller due to reduced cooling. 

Using the inverter in high altitudes may also reduce nominal power of the inverter because of less heat discharge. 
As a rule of thumb, the reduction of nominal power is approximately 1.5% per 100m elevation.  

13.2 Installation 

These units must be only installed by qualified, authorized and trained personnel familiar with the locally 
applicable standards and taking into consideration all relevant safety guidelines and measures!   

Before installing the unit check for correct DC-Voltage and power level of the inverter. 

The Inverter may be installed in any position. Install the inverter in a dry, well ventilated and dust free location. It 

must be installed out of reach for unauthorized personnel especially children’s. Do not i

nstall the inverter in the 

same compartment as the batteries. 

Never use or install the inverter in locations where there is gas or explosive danger! 

For proper cooling of the Inverter ensure that the airflow is not obstructed and keep a clearance distance of 2.5cm 
to other units. If the inverter is installed in a closed compartment the nominal power may be reduced. 

In order to keep the battery cables as short as possible  (max. 3m) locate the inverter close to the DC-Distribution 
or Battery. Be aware that during charging of batteries an explosive gas can be generated.  

13.3  

DC-Wiring 

Position of the switch on the front panel must be OFF. 
Caution! First connect the assembled DC-Cables with the inverter and in a second step connect it with the bat-
tery! Always connect first the neutral wire with the battery! 

A high power fuse must be installed direct to the battery to protect the DC-Wiring. DC 

 current according to the 

table below. 
Not installing a fuse may result in melting or even burning DC-Cables in case of excessive overload or failure of 
the inverter. 

The way of wiring has influence on the EMC behaviour of the system. Most problems using inverter are because 
of unprofessional wiring. Lay the cables in a metal duct. If this is not possible the cables should be twisted and lay 
parallel to a metal bar.  

YOUR CONNECTION TO SAFETY

Thiele KG 

• V

orderer W

einberg 26 • D-71522 Backnang • T

el.: +49 (0)7191 3560-0 

• Fax.: +49 (0)7191 3560-19 

• info@thiele-kg 

• www

.thiele-kg.de

Thiele KG 

• V

orderer W

einberg 26 • D-71522 Backnang • T

el.: +49 (0)7191 3560-0 

• Fax.: +49 (0)7191 3560-19 

• info@thiele-kg 

• www

.thiele-kg.de

YOUR CONNECTION TO SAFETY

klick to

www

u-s-v

YOUR CONNECTION TO SAFETY

klick to

www

ACDC-DCDC

YOUR CONNECTION TO SAFETY

klick to

www

SYSTEME

YOUR CONNECTION TO SAFETY

klick to

www

CONTACT

YOUR CONNECTION TO SAFETY

klick to

www

CALLBACK

Summary of Contents for UPSW2000

Page 1: ...9 info thiele kg www thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg www thiele kg de YOUR CONNECTION TO SAFETY klick to www u s...

Page 2: ...can not accept any liability for damages or costs arising due to the use of these inverters 2 Distributor s address 3 Retail dealer s address Date of purchase YOUR CONNECTION TO SAFETY Thiele KG Vorde...

Page 3: ...Output Current Indicator 10 17 3 Output Watts Indicator 10 17 4 Input DC Voltage Indicator 10 17 5 Temperature Indicator 10 17 6 Output Frequency DC Indicator 10 17 7 Over voltage protection indicato...

Page 4: ...tion required for service or delivery of spare parts can be derived from the type number plate Modifications or breaking the warranty label without a written permission from RIPEnergy AG means that wa...

Page 5: ...age If any damage due to transport is visible imme diately contact your dealer for further instructions Keep the original packing in case you need it to transport the inverter later 9 Environmental pr...

Page 6: ...y heat up to 80 C Never obstruct louvers nor place other items on the inverters enclosure If ventilation is not sufficient the unit may overheat and an automatic shut off may occur Even if DC Wiring i...

Page 7: ...correct DC Voltage and power level of the inverter The Inverter may be installed in any position Install the inverter in a dry well ventilated and dust free location It must be installed out of reach...

Page 8: ...is protected against overload and short circuit we recommend to use an AC Circuit breaker of correct size For safe operation it is necessary to connect earth PE and neutral N of the inverter output t...

Page 9: ...rom right to left 16 Operation The Inverter is controlled by a ON OFF switch located on the front panel of the inverter Engaging Set the power switch to the ON position you will hear three beep After...

Page 10: ...r LED displays light on TEMP as show as internal operating temperature value 17 6 Output Frequency DC Indicator LED displays light on Hz as show as output frequency value Select VAC AMP WATT VDC TEMP...

Page 11: ...n indicator OLP The overload indicator indicates that the power inverter has shut down A manual reset is necessary switch it OFF and ON again to restart operation This is a safety function to protect...

Page 12: ...have enough power available In this mode the load is connected to inverter In case of inverter failure low battery overload etc the AC Output switches to grid mains power Switch over time is less tha...

Page 13: ...info thiele kg www thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg www thiele kg de YOUR CONNECTION TO SAFETY klick to www u s v...

Page 14: ...load is smaller than nominal power of inverter check if ventilation of the inverter is blocked Maybe the ambient temperature is too high If load is exceeding nominal power of inverter reduce the load...

Page 15: ...aler or nearest service center They will help you with further instructions 4 If he recommends sending the unit back for repair use the original packing 5 Include a copy of the invoice Warranty repair...

Reviews: