![Thiele TWN 1472 Mounting Instructions Download Page 3](http://html1.mh-extra.com/html/thiele/twn-1472/twn-1472_mounting-instructions_1106881003.webp)
MOUNTING INSTRUCTIONS
LASHING POINTS TWN 1472, TWN 1473
THIELE GmbH & Co. KG
# identifies revisions
www.thiele.de | [email protected]
B09059-C
replacement for B09059-B
© All rights reserved
EN 08.2021
3 | 4
5.8
Welding process MAG
Welding process
Metal active gas welding (MAG) EN ISO 9606-1; No. 135
Welding groove
See sketch, taking into account EN ISO 9692-1
#
Quality grade
For all layers according to EN ISO 5817 - C
#
Wire electrode
EN ISO 14341-A:2011: ISO 14341-A-G 46 4 M21 3Si1
Possible alternatives must be selected and checked by the welding supervisor on site.
#
Welding position
EN ISO 9606-1: PA, PB, PC, PF
#
Preheating of parent metal
Thickness
≥
20 mm: 150 °C
#
Interpass temperature
≤ 400 °C
Postweld heat treatment
Thickness
≥
40 mm: Tempering at max. 400 °C
1)
or apply quenching and tempering layer technology
#
Pass
Root run
Intermediate run/
#
Final run
Temper pass
Wire electrode diameter
1 mm
1,2 mm
1 or 1,2 mm
Welding current (=)
130
–
200 A
135
–
290 A
See root run or stringer pass.
Note: The quench and temper
layer must only be applied to the
weld metal. Contact with the base
metal must be avoided.
#
Electrode polarity
(= +)
(= +)
Voltage
19
–
25 V
19
–
32 V
Shield gas ISO 14175; M21
10
–
12 l/min
12
–
14 l/min
Kind of pass
Stringer pass
Stringer pass
1)
but not more than 20 °C below the tempering temperature
5.9
Manual welding process MMA
Welding process
Manual metal arc welding (MMA) EN ISO 9606-1; No. 111
Welding groove
See sketch, taking into account EN ISO 9692-1
#
Quality grade
For all layers according to EN ISO 5817 - C
#
Wire electrode
EN ISO 2560 A:2010: min. ISO 2560-A-E 38 4 B 42 H5
2)
#
Possible alternatives must be selected and checked by the welding supervisor on site.
#
Welding position
EN ISO 9606-1: PA, PB, PC, PF
#
Preheating of parent metal
Thickness
≥
20 mm: 150 °C
#
Interpass temperature
≤ 400 °C
Postweld heat treatment
Thickness
≥
40 mm: Tempering at max. 400 °C
3)
or apply quenching and tempering layer technology
#
Pass
Root run
Intermediate run/
#
Final run
Alternative final run
Temper pass
Wire electrode diameter
2,5 mm
3,2 mm
4,0 mm
2,5 or 3,2 or 4,0 mm
#
Welding current (=)
80
–
110 A
100
–
140 A
130
–
180 A
See root run or stringer pass.
Note: The quench and temper layer
must only be applied to the weld
metal. Contact with the base metal
must be avoided.
#
Electrode polarity
(= +)
(= +)
(= +)
Voltage
-
-
-
Shield gas ISO 14175; M21
-
-
-
Kind of pass
Stringer pass
Stringer pass
Stringer pass
2)
Re-drying according to manufacturer's instructions
3)