Thiele TWN 1472 Mounting Instructions Download Page 3

MOUNTING INSTRUCTIONS 

LASHING POINTS TWN 1472, TWN 1473 

 
 

 

THIELE GmbH & Co. KG

 

 

# identifies revisions 

www.thiele.de | [email protected] 

 

B09059-C 

replacement for B09059-B 

© All rights reserved 

EN 08.2021

 

3 | 4

 

5.8

 

Welding  process MAG 

Welding  process 

Metal active gas welding (MAG) EN ISO 9606-1; No. 135 

Welding  groove 

See sketch, taking into account  EN ISO 9692-1

 #

 

Quality grade 

For all layers according to EN ISO 5817 - C

 #

 

Wire electrode 

EN ISO 14341-A:2011: ISO 14341-A-G 46 4 M21 3Si1 
Possible alternatives must be selected and checked by the welding supervisor on site.

 #

 

Welding  position 

EN ISO 9606-1: PA, PB, PC, PF

 #

 

Preheating of parent metal 

Thickness 

 20 mm: 150 °C

  #

 

Interpass temperature 

≤ 400 °C

 

Postweld  heat treatment 

Thickness 

 40 mm: Tempering at max. 400 °C 

1)

 or apply quenching and tempering layer technology

  #

 

Pass 

Root  run 

Intermediate run/

  #

 

Final run 

Temper pass 

Wire electrode diameter 

1 mm 

1,2 mm 

1 or 1,2 mm 

Welding  current (=) 

130 

 200 A 

135 

 290 A 

See root run or stringer pass. 

 

Note: The quench  and temper 

layer must only be applied  to the 

weld metal. Contact  with the base 

metal must be avoided.

 #

 

Electrode polarity 

(= +) 

(= +) 

Voltage 

19 

 25 V 

19 

 32 V 

Shield  gas ISO 14175; M21 

10 

 12 l/min 

12 

 14 l/min 

Kind of pass 

Stringer pass 

Stringer pass 

1)

 

but not more  than 20 °C below  the tempering temperature

 

 

5.9

 

Manual  welding  process MMA 

Welding  process 

Manual metal arc welding (MMA) EN ISO 9606-1; No. 111 

Welding  groove 

See sketch, taking into account  EN ISO 9692-1

 #

 

Quality grade 

For all layers according to EN ISO 5817 - C

 #

 

Wire electrode 

EN ISO 2560 A:2010: min. ISO 2560-A-E 38 4 B 42 H5 

2)

 #

 

Possible alternatives must be selected and checked by the welding supervisor on  site.

 #

 

Welding  position 

EN ISO 9606-1: PA, PB, PC, PF

 #

 

Preheating of parent metal 

Thickness 

 20 mm: 150 °C

  #

 

Interpass temperature 

≤ 400 °C

 

Postweld  heat treatment 

Thickness 

 40 mm: Tempering at max. 400 °C 

3)

 or apply quenching and tempering layer technology

  #

 

Pass 

Root  run 

Intermediate run/

  #

 

Final run 

Alternative final run 

Temper pass 

Wire electrode diameter 

2,5 mm 

3,2 mm 

4,0 mm 

2,5 or 3,2 or 4,0 mm

 #

 

Welding  current (=) 

80 

 110 A 

100 

 140 A 

130 

 180 A 

See root run or stringer pass. 

 

Note: The quench  and temper layer 

must only be applied to the weld 

metal. Contact  with the base metal 

must be avoided.

  #

 

Electrode polarity 

(= +) 

(= +) 

(= +) 

Voltage 

Shield  gas ISO 14175; M21 

Kind of pass 

Stringer pass 

Stringer pass 

Stringer pass 

2)

 

Re-drying  according  to manufacturer's  instructions  

3)

 

but not more  than 20 °C below  the tempering temperature

 

 

 

Reviews: