Summary of Contents for PST700w Series

Page 1: ...info thiele kg de www thiele kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de YOUR CONNECTION TO SAFETY klick to www...

Page 2: ...afety precautions 13 6 2 Precautions when working with batteries 13 7 Appendices A 7 1 110VAC Dip switch 14 7 2 220VAC Dip switch 14 YOUR CONNECTION TO SAFETY Thiele KG Vorderer Weinberg 26 D 71522 Ba...

Page 3: ...hen appliances microwave ovens refrigerators and freezers coffee makers blenders ice markers toasters 1 1 5 Industrial equipment metal halide lamp high pressure sodium lamp 1 1 6 Home entertainment el...

Page 4: ...0 1 0 Protection Overload Short Circuit Reverse Polarity fuse Input Undervoltage Input Overvoltage Over Temperature LED Light On Line By Pass Power OLP UVP OVP OTP Safety EN60950 1 2006 IEC60950 1 200...

Page 5: ...e kg de Thiele KG Vorderer Weinberg 26 D 71522 Backnang Tel 49 0 7191 3560 0 Fax 49 0 7191 3560 19 info thiele kg de www thiele kg de YOUR CONNECTION TO SAFETY klick to www u s v YOUR CONNECTION TO SA...

Page 6: ...Undervoltage Overvoltage Protection OTP on Over Temperature Protection 2 1 4 AC input and output connector WARNING Do not connect the AC source to the inverter s AC output terminal do not connect AC l...

Page 7: ...l safety hazard WARNING Shock Hazard Before proceeding further carefully check the inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not con...

Page 8: ...and prolonged exposure that will damage the inverter 2 4 Quick Hook Up and Testing 2 4 1 Unpack and inspect the power inverter check to see that the power switch in the OFF position 2 4 2 There is an...

Page 9: ...ng installation AC input and output ground wires are connected to the inverter The AC input ground wire must connect to the incoming ground from your AC utility source The AC output ground wire should...

Page 10: ...ndards requires us to test and recommend specific GFCI Our company has tested the following GFCI protected 20A receptacles and found that they functioned properly when connected to the output of the i...

Page 11: ...warranty Model No Wire AWG Inline Fuse YK PST1270 YK PST1270E 4 100A YK PST2470 YK PST2470E 6 50A YK PST4870 YK PST4870E 8 30A YOUR CONNECTION TO SAFETY Thiele KG Vorderer Weinberg 26 D 71522 Backnan...

Page 12: ...ceeded 12V 24V 48VDC version Ref point 2 7 1 2 7 3 Under Voltage Protection indicator UVP The under voltage indicator indicates that the power inverter has shut itself down because its input voltage f...

Page 13: ...l shock or fire Problem and Symptom Possible Cause Solution Low output voltage 110V 95 105VAC 220V 190 210VAC Using average reading voltmeter Use true RMS reading meter and cable Ref point 2 4 7 Load...

Page 14: ...reduce risk of hazard do not cover or obstruct the ventilation openings Do not install the inverter in a zero clearance compartment Overheating may result 6 1 2 To avoid a risk of fire and electronic...

Page 15: ...Q Hz S2 S3 BAUD RATE S4 S5 VOLTAGE OUTPUT VAC ON 60 OFF OFF 2400 OFF OFF 200 OFF 50 OFF ON 4800 OFF ON 220 ON OFF 9600 ON OFF 230 ON ON 19200 ON ON 240 S1 FREQ Hz 50Hz 60Hz S2 S3 BAUD RATE 2400 4800 9...