Thiel USS SmartSub Owner'S Information Download Page 8

Fuse Replacement

Specifications

If the subwoofer is completely dead, with no indicator 

light on, the main fuse has probably blown and will need 

to be replaced. The fuse should be replaced only with an 

equivalent type. The fuse type is 5 x 20 mm size, slo-blow 

or time delay type, with a rating of 5 amp for 230 volt units 

and 8 amp for 115 volt units. Fuse reference numbers are 

T5AL or T8AL. Or, contact THIEL for a replacement fuse.
Replace the fuse by first unplugging the power cord from 

the subwoofer. Unscrew the 10 hex-head retaining screws 

using a 9/64” wrench, and then remove the amplifier panel 

from enclosure. Remove the fuse from the socket located 

as pictured. Replace with specified value, then replace the 

amplifier panel into the enclosure. 

Amplifier 

Power output (at 120 or 240 line voltage)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  550 watts RMS

 

Line voltage   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .90-130 or 180-260

Cabinet 

Response.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Normal input: 20 Hz–300 Hz, ±0.5 dB;  LFE input  20 Hz–300 Hz, ±0.5 dB

 

Bandwidth   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  Normal input  20-800 Hz, ±3 dB;  LFE input: 20–800 Hz, ±3 dB  

 

Sensitivity.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1 volt for 120 dB @ 1 m, 4

π

 

Size (inches height, width, depth)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 20, 10

½

, 15

 

Weight (pounds)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  57

 

Driver .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10”

 

Driver displacement (cu in) .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  65

 

Output dB @ 20Hz / 30Hz (corner placement) .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  99 / 106

THIEL 

• 1026 Nandino Boulevard, Lexington, Kentucky 40511-1207

Telephone: 859-254-9427 • E-mail: [email protected] • Web: www.thielaudio.com

0412

Register your warranty online at 

www.thielaudio.com

Warranty

THIEL warrants every THIEL SmartSub system against defects in materials and workmanship to the original owner for a period 

of ten years for the drivers and cabinet, and five years for the electronics from the date of purchase. THIEL will, at no charge, 

replace any defective part and make any repairs necessary to ensure its proper performance when the defective unit is returned to 

us postpaid.  
This warranty does not cover damage due to accident or abuse and is void if the unit has been tampered with.
This warranty is automatic and no registration is required.  This warranty gives you specific legal rights.  You may also have other 

rights which are particular to your state.

The following information is for your records.
 

Serial Numbers______________________________      

Purchase Date_______________________________

 

Purchased From_____________________________

Summary of Contents for USS SmartSub

Page 1: ... Auto shutdown 6 Feet 6 SmartSub Back Panel Detail 7 Fuse Replacement 8 Specifications 8 Warranty 8 Thank you for purchasing a THIEL SmartSub system It has been engineered to provide a very high level of performance and also incorporates innovative and patented concepts in its design to solve the several special problems subwoofer systems usually exhibit Consequently it performs at a very high lev...

Page 2: ...ment controls patented match the subwoofer s performance to its environment whether away from walls in a corner or anything in between These controls correct for both the general increase in level and for the partial cancellation of certain frequencies caused by a nearby wall By providing correction of these effects for both the side and rear walls SmartSubs provide accurately balanced uniform res...

Page 3: ...EL PXO5 passive crossover 3 With a combination of passive crossover and LFE connection in a home theater application 4 In true crossover mode reproducing low frequency information redirected to it by an external active crossover The configuration chosen will determine your required equipment hookup connections and processor settings Which system configuration is best for you depends mainly on the ...

Page 4: ...uld and the bass to be reproduced better This is implemented by telling the processor that your main speakers are small The limitation of this bass management approach is the poor balance and integration between the subwoofer and the main speakers that the processor s generic filters provide It may be suitable for low standard video systems and will seldom be suitable for music THIEL PXO Passive C...

Page 5: ...rong Unfortunately an SPL meter cannot be used to adjust subwoofer level due to differences in bandwidth between the subwoofer and the main speakers The placement settings should be adjusted to correspond to the placement of the subwoofer Set the Side Wall Distance to the distance from the side of the subwoofer to the side wall and the Rear Wall Distance to the distance from the rear of the subwoo...

Page 6: ...the subwoofer is placed near a wall and even more output is available when placed near a corner of the room If very high output is desired in large rooms corner placement can be used with little trade off in sound quality For use in very large rooms greater than 4 000 ft3 more than one USS may be required if very high playback levels are desired CAUTION The SmartSub has built in electronics Do not...

Page 7: ...driven by a THIEL passive crossover If the Normal input is used then this connector can be used to connect to an ad ditional subwoofer DC voltage 5 25 volts to this jack will turn the amplifier on if the auto on switch is set to auto Removing the voltage turns the amp off The On position turns the am plifier on provided that the main power switch is on The Auto position allows the amplifier to aut...

Page 8: ...120 dB 1 m 4π Size inches height width depth 20 10 15 Weight pounds 57 Driver 10 Driver displacement cu in 65 Output dB 20Hz 30Hz corner placement 99 106 THIEL 1026 Nandino Boulevard Lexington Kentucky 40511 1207 Telephone 859 254 9427 E mail service thielaudio com Web www thielaudio com 0412 Register your warranty online at www thielaudio com Warranty THIEL warrants every THIEL SmartSub system ag...

Reviews: