Diagnostic messages
TIM 2015 performs various diagnostics at power-on. If a problem is detected one of the following seven messages should be displayed. The
parts mentioned that may require your attention are illustrated on the following page.
Please set Time
This indicates no valid time has been set and retained in the RTC module.
Set the time and if it is not retained after power-off, check whether the CR2032 coin-cell has become dislodged or requires
replacement.
Please set Date
This indicates no valid date has been set and retained in the RTC module.
Set the date and if it is not retained after power-off, check whether the CR2032 coin-cell has become dislodged or requires
replacement.
Error: 01 VoiceHW
The Catalex sound module is not responding.
Try powering off and on again. If the message persists, check the module’s connections and try reseating the microcontroller IC
in its socket.
Error: 02 SDCARD
The microSD card carrying the voice files is not inserted properly. Alternatively you might see this message if the microSD card becomes
corrupted (which is unlikely).
Try powering off and on again. If the message persists, re-seat the microSD card in its socket in the Catalex player. Try using
another microSD card or check the card for file corruption, etc. using a PC card reader.
Summary of Contents for TIM 2015
Page 1: ...TIM 2015 Technical Manual v1 February 2018 Page 1 TIM 2015 Speaking Clock TECHNICAL MANUAL...
Page 9: ...TIM 2015 Technical Manual v1 February 2018 Page 9 Board dimensions 140 x 85mm...
Page 10: ...TIM 2015 Technical Manual v1 February 2018 Page 10 Board layout...
Page 11: ...TIM 2015 Technical Manual v1 February 2018 Page 11 Circuit diagram...