13
INSTALLATION
Electrical Connection
The spark ignition generator must only be connected to a suitable 12V DC battery. Sheathed
spade connectors should be used to connect the spark generator to the power supply.
SERVICING
Do not modify this appliance. All servicing must be carried out by an approved and competent
person. Before any service work is started the appliance must be left to cool and be
disconnected from both the gas and electrical supplies. After each service the appliance must
be checked for gas soundness.
Details of the injector orifice size are provided within the specification table on page 4. To verify
the system is operating at the correct pressure, a pressure test point is provided on the gas
manifold, located below the control panel. The pressure is measured with the Semi Rapid
burner on a high flame and with an inlet pressure of 2.75 kPa (Universal LPG).
To remove the hob.
Isolate the gas supply and disconnect inlet pipe
Disconnect 12v power wires to spark generator.
Lift the glass lid and unscrew the appliance from the worktop - see Fig. 3 on page 7 for fixing
details. Lift and place the hob onto a suitably protected surface.
Hob burner gas valve removal/replacement.
Shut off gas supply and disconnect gas supply pipe from the unit.
Remove the hob from the worktop as above.
Remove the appropriate control knob by pulling up on the knob.
From underside of hob disconnect the appropriate thermocouple at the gas valve.
Unscrew the appropriate gas supply pipe nut.
Remove the appropriate gas valve clamp by unscrewing the two screws.
Unscrew the gas valve retaining nut.
Remove the gas valve.
Replace the valve and gasket. Refit using the reverse of the above procedure.
To ensure correct operation observe the following installation requirements:
•
Build the appliance into a self-contained cabinet which is not connected
to externally vented chambers in adjacent furniture, other than the
correct size gas dispersal hole.
•
Holes for cables & pipes should have minimum clearances.
•
A gas dispersal hole should be fitted, this must not exceed Ø25mm
•
Cupboards below appliance must not allow gas to enter the living area.
•
Air vents
and gas dispersal holes must be kept clear
•
If this appliance is not installed in accordance with the instructions and
tolerances detailed herein, we the manufacturer can not be held
responsible for any problems that occur, or poor performance that is
perceived/witnessed