![Theta Digital Dreadnaught II Owner'S Manual Download Page 23](http://html1.mh-extra.com/html/theta-digital/dreadnaught-ii/dreadnaught-ii_owners-manual_1106470023.webp)
Figure 7 – Dreadnaught II RS232 Jumper Settings
RS232 Jumper Settings
There are 2 possible Baud rates:
9600
and
19200
. The factory default is
19200
. To change the baud rate to
9600
,
move the jumper to the center and top pins (if the RS232 board is orientated as in figure 7).
The
STATUS
can be returned to the controller either: automatically every time a parameter has changed, or the user
can request it manually. The factory default is
AUTO
. To set the Echo
STATUS
to return status information only upon
request, move the
AUTO
/
REQ
jumper to the top pins, or nearer to
REQ
on the RS232 board.
The three
SELECT
jumpers are not currently implemented.