CONNECTING THE WATER SUPPLY

Pipework is not supplied

All pipework should be installed using good plumbing practice.

We recommend 22mm mains cold water supply is used.

Install a Stop Cock Valve before the cold water inlet assembly on

the incoming mains water supply so the unit can be isolated if

required.

COLD WATER VALVE

The combined cold water valve (supplied) can be connected

anywhere on the cold water mains prior to the unit. It can even be

located at a point near to where the mains supply enters the

premises if this is more convenient. When installing the cold water

valve, ensure that the arrow is pointing in the same direction as the

mains water supply flow when connecting, see fig 2.

The cold water balancing port, on the valve, allows you to connect

the cold water mains to the rest of the property thus giving

balanced pressure throughout. If this facility is not required leave

the cap on.

DRAIN TAP

A drain tap to drain the unit must be fitted to the cold-water inlet

pipe somewhere between the  unit and the cold water

valve assembly and at as low a level as possible, see fig. 1.

PIPEWORK TO TAPS

Ideally a 22mm pipe run should supply the outlets throughout the

property with short lengths (max 1 metre) runs of 15mm going to

baths, showers, and basin taps. Smaller bore pipe can be used to

suit taps.

SECONDARY CIRCULATION

This is particularly easy to fit on unvented units; a Swept Tee

(not supplied) is needed for all indirect models if secondary

circulation is required, see page 6 fig. 3 for fitting. A non-return

valve (not supplied) must be fitted to prevent backflow. You will

need a pump to circulate the hot water (not supplied). The return

feed is in 15mm pipe and all work can be done on site.

Fig.1

Fig.2

Typical Indirect Tank installation using external expansion vessel

Cold water inletvalve assembly

PRESSURE REDUCING         VALVE

SET AT 3 BAR

WATER FLOW INLET SIDE OF TANK

WATER FLOW FROM EXPANSION
TANK TO 22MM FEMALE THREAD

BEHIND COVER

BLANKED
PORT

WATER FLOW
HOT WATER OUTLET

PRIMARY FLOW

PRIMARY RETURN

TWIN
THERMOSTAT

IMMERSION
HEATER

WATER FLOW
TO COIL INLET

WATER FLOW
FROM COIL INLET

7 BAR / 90 DEGREES
PRESSURE &
TEMPERATURE
RELIEF VALVE.

TUNDISH

WATER FLOW
TO OVERFLOW

WATER INLET

DRAIN

COCK

SECONDARY

RETURN FLOW

SWEPT TEE

EXPANSION VESSEL

(WALL MOUNTED)

WATER FLOW TO

MANFOLD VIA

FLEXIBLE HOSE

6 BAR

EXPANSION

RELIEF

VALVE

PRESSURE
REDUCING VALVE
SET AT 3 BAR

WATER FLOW
INLET SIDE OF TANK

BLANKED
PORT

WATER FLOW

FROM EXPANSION

TANK TO 22MM

FEMALE THREAD

BEHIND COVER

6 BAR

EXPANSION

RELIEF

VALVE

BALANCED

COLD WATER

OUTLET

Summary of Contents for unvented water heater

Page 1: ...unvented water heater installation manual 3bar kit version...

Page 2: ...LAND BUILDING REGULATION P5 AFTER INSTALLATION THE BENCHMARK LOG BOOK MUST BE COMPLETED AND LEFT ALONG WITH THESE INSTRUCTIONS WITH THE HOUSEHOLDER FOR FUTURE REFERENCE INSTALLATION INSTRUCTION MANUAL...

Page 3: ...jam or leak no noise from tank filling All your water hot and cold is direct from the mains Site the unvented water heater wherever convenient Your vessel fills your bath in minutes and will run two a...

Page 4: ...05 litres and 80 litre DH direct model 2 Elements on DH direct models from 130 up to 305 litres Additional elements from 215 to 305 litres are available on request Cold water control valve comprising...

Page 5: ...roperty with short lengths max 1 metre runs of 15mm going to baths showers and basin taps Smaller bore pipe can be used to suit taps SECONDARY CIRCULATION This is particularly easy to fit on unvented...

Page 6: ...6 SECONDARY CIRCULATION CONNECTION DIAGRAM Fig 3 2 2 PORT S PLAN VALVE SYSTEM GUIDANCE LAYOUT ONLY Fig 4...

Page 7: ...er thermostat fails WARNING Ensure that the immersion heater thermostat is set at 60 degrees Celsius FITTING THE THERMAL CUT OUT PRIMARY CONNECTIONS The motorised valve supplied and the thermal cut ou...

Page 8: ...equivalent EXTERNAL EXPANSION TANK This smaller tank is connected to the cold water inlet side of the vessel Mount the tank according to separate manufacturers instructions provided with the External...

Page 9: ...ully ii downward discharges at low level i e up to 100mm above the external surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children may play or otherwi...

Page 10: ...perate change the complete heating element assembly Important In the event of an over heat situation reset all thermal cutouts If hot water discharges from Tundish WARNING Do not turn the mains water...

Page 11: ...egular service stamp by a qualified unvented installer Exclusions The guarantee does not cover The effects of large scale build up Any labour charges associated with replacing the unit or outs parts A...