background image

 

1. 

WARNING!

 

Before installation and operation, please refer to the "operating Instructions" (hereinafter the 
"instruction"). 
In connection with the still ongoing work to improve the quality of the product, the design of 
products can be changed and not included in this manual, however, does not reduce the 
performance of the product. 
 

2. GENERAL

 

This manual is designed for convector electric THERMOVAL model T17 and TX (hereinafter 
referred to as heaters). 
Heaters belong to the class of modern heating equipment stationary type, using hot air for 
heating buildings and building installations. 
Radiators with degree of protection IP20 are designed for use in traditional areas. Radiators 
IP24 protection against water droplets, are intended for use in all types of premises. 
 
Heaters  are  designed  for  fixed  installation  on  the  wall,  but  their  design  also  allows  for 
installation  on  the  floor,  movable  or  immovable  legs,  which  are  purchased  separately. 
Heaters are provided with a thermostat to adjust and maintain the desired temperature in the 
room  regulator  staged  output  power  in  a  protection  against  overheating,  and  protection  of 
rooms  against  freezing  (to  keep  the  room  temperature  in  the  range  of  from  +  5  to  +  7 

°

  C. 

which  prevents  freezing    room  while  maintaining  the  lowest  level  of  power  consumption). 
The regime of work - all day, automatically. 
 
When buying a heater, be sure to check that the device is functioning properly and is free from 
mechanical damage and whether the supplied set of elements is consistent with the list by. p. 3 
of  this  manual.  Carefully  check  the  completeness  and  correctness  of  the  fulfillment  of  the 
guarantee  and  coupons  are  cleaved  and  the  presence  of  a  stamp  dealer. 
Keep proof of purchase, this manual, warranty card and packaging during the warranty period 
of the heater. Attached to the radiator while sales documentation in the event of loss can not 
be restored. 
 

REMEMBER:

  failure  to  comply  with these  recommendations,  in  case of mechanical  damage, 

can lead to loss of the right to warranty service. 

 

TECHNICAL DATA

 

Supply voltage,                                                                   V 230 

±

 10 

Frequency                                                                              50 Hz 

± 1

 

Class of protection against electric shock                                          II 
The degree of protection provided by the housing         IP 20 or IP 24 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TX

Page 1: ...ELECTRIC CONVECTOR WITH A POSSIBILITY OF MOUNTING LEGS MODEL TX T17 OPERATION INSTRUCTIONS ...

Page 2: ...maintain the desired temperature in the room regulator staged output power in a protection against overheating and protection of rooms against freezing to keep the room temperature in the range of from 5 to 7 C which prevents freezing room while maintaining the lowest level of power consumption The regime of work all day automatically When buying a heater be sure to check that the device is functi...

Page 3: ...hose taking a bath located in the shower or in the pool Protect the device from getting to the inside of foreign objects or paper Use the device only for its intended purpose heater is not intended for outdoor use Do not use a heater with a damaged cord We must be careful that the power cord does not touch the hot surface of the radiator To avoid burns do not touch the bare hand outlet grille and ...

Page 4: ...requirements for the radiator presented in Chapter 2 of this manual voltage protect the system power supply the quality of cables and sockets which will be connected to the heater are relevant for the product If necessary please contact dealer or the official service representative 5 4 In the case of stationary installation of the heater must be noted on a wall place the mounting holes see Figure ...

Page 5: ...hrooms swimming pool etc in the zone 2 where a person located in the bath shower or swimming pool can reach a heater or its cord Power outlets for heaters should be installed at least 25 cm above the floor and out of the zone 2 5 6 Press the button on the position of incorporation and then move the knob gradual power control from the off position 0 The thermostat knob sets the position sign knob s...

Page 6: ...eater by moving the key switch to I key progressive regulator positions I and II When the room temperature reaches the desired value you can check the temperature with a thermometer slowly turn the thermostat to reduce the numerical values looking at the selection located on the knob until the function heating is switched off accompanied by the characteristic click The selected temperature will au...

Page 7: ...th a brush and a vacuum cleaner wipe the case with a damp cloth Do not use abrasive or aggressive 8 TRANSPORT AND STORAGE 8 1 radiators in the manufacturer s packaging can be transported by all types of covered means of transport that will provide protection against rain and mechanical damage according to the rules for their transport defined by the selected carrier During transport the temperatur...

Page 8: ...prevention activities These works are carried out for an additional fee Guarantee does not include Products which are damaged by external factors such as voltage drop lightning fire water damage as well as neglect and other factors not under the control of the manufacturer Products which have ceased to operate due to improper connection to the network and also because of the deviation of the elect...

Reviews: