background image

USER INSTRUCTIONS

 

 

 

3

Starting - up the boiler 

 

Open  the  gas  Isolation  valve  located  under 
the boiler. 

 

Switch  on  the  boiler  by  placing  the  ON/OFF 
switch  (1)  in  the  ON  position  (see  “Control 
panel”). 

 

The  boiler  will  light  automatically  (with  the 
WINTER mode selected and room thermostat 
connected). 

 

Check  that  there  are  no  flashing  numbers  on 
the  display  8  (see  error  codes).  If  code  H2O 
appears  on  the  display  8  this  denotes  that 
there  is  no  water  in  the  boiler. Consequently, 
fill  the  system  as described in section “Filling 
the system”. 

 

  “SUMMER” mode  

To switch boiler operation to “SUMMER” mode, press button 6 (see fig. 1). The boiler will only work for the D.H.W 

system.  The  “SUMMER”  mode  setting  of  the  boiler  is  signalled  by  the  symbol

 

lit  continuously  on  the  control 

panel.  

The  automatic  ignition  system  will  light  the  burner  every  time  there  is  a  demand  for  domestic  hot  water.  In  this 

case, the symbol

 

on the control panel will flash.  

 

  “WINTER” mode 

To switch boiler operation to “WINTER” mode, press button 6 (see fig. 1). The boiler will only work for the central 

heating  system.  The  “WINTER”  mode  setting  of  the  boiler  is  signalled  by  the  symbol

 

lit  continuously  on  the 

control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the 

symbol

 

on the control panel will flash. 

 

  “SUMMER-WINTER” mode  

To switch boiler operation to “SUMMER/WINTER” mode, press button 6 (see fig. 1). The boiler will work for both 
central  heating/D.H.W  systems.  The  “SUMMER/WINTER”  mode  setting  of  the  boiler  is signalled by the symbols 

 

 lit continuously on the control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating or domestic hot 

water, the functioning is signalled by the symbols 

 

flashing continuously on the control panel. 

 

  Regulating the heating temperature 

The heating temperature is regulated by knob (see fig.1). 

 

Rotating the knob anticlockwise reduces the temperature. 

 

Rotating the knob clockwise increases the temperature. 

 

The  range  of  temperature  settings  for  the  central  heating  runs  from  a  minimum  of  30°C  to  a  maximum  of  

80°C, or, in the case of low temperature operation,  from a minimum of 25°C to a maximum of 59°C. 

 

 

D.H.W temperature control 

 

The domestic hot water temperature is regulated by knob (see “Control panel”). 

 

Rotating the knob anticlockwise reduces the temperature. 

 

Rotating the knob clockwise increases the temperature. 

 

The range of temperature settings for the domestic hot water runs from a minimum of 35°C to a maximum  of 

60°C.

 

6

7

5

4

3

2

1

8

Fig. 1

 

Reviews: