Advanced settings
MENU DESCRIPTION
RANGE
DEFAULT
01
Heating events
2, 4 or 6 per day
4
02
Sensor mode
Room, Floor, Room & floor limit
Floor
03
Temperature calibration
Floor -5 to 5°C, Room -5 to 5°C
0°C
04
Open window
On / Off
Off
Sensing time
1 - 30 minutes
1 minute
Temp drop limit
2 - 4
°
C
3
°
C
Off time
10 - 60 minutes
15 minutes
05
Adaptive start
On / Off
Off
06
Floor temperature limit
20 - 45
°
C
35
°
C
07
Frost protection
On / Off
Off
Frost protection temperature
5 - 15
°
C
5
°
C
08
Brightness
1 - 99%
80%
10
Temperature tolerance
0.5, 1, 2 or 3
°
C
1
°
C
11
Energy use
Power rating 0 - 4500W
0W
Power consumption
-
12
Factory reset
-
-