ThermoSphere HA24-100E Instruction Manual Download Page 12

 

                                            

 

Figure 13 

Note3. 

Connect the wire according to wiring diagram as sh

own in figure 11 (100E) or 12 

(150E). 

Note4.

 The external temperature control (external thermostat) should comply with UL or ETL 

standard requirements.

 

Note5.

 The lead wire of external temperature control (

external

 thermostat) must have a 

minimum gauge of 16 AWG.

 

 

External thermostat installation:  

 
1.  Pop the piece out to open the hole                                2. Remove both screws 

 

                   

 

Figure 14A                                                                 Figure 14B  

 

3. 

Strip away the cover of lead wire for 50mm       4. 

.Twist the wire through the end                   

  From the external control box. 
 
 
 

Figure 14C                                                                                Figure 14D 
 
 

Summary of Contents for HA24-100E

Page 1: ...re extremely sensitive to the fumes produced during the first time use of many appliances These fumes are not harmful to humans but we recommend that you do not use your heater around birds and small...

Page 2: ...TS Important Instructions 3 Description and Specifications 4 5 General Safety Information 6 Locating the heater 7 Installation 8 10 Connecting the power 11 14 Operating Instructions 15 17 Maintenance...

Page 3: ...ub or other water container 8 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel 9 Do not insert or allow any foreign objects to enter any ventilat...

Page 4: ...of 51615 150E or 34410 100E BTU per hour It includes horizontal and vertical air flow and a built in thermostat with overheating safety thermal cut out SPECIFICATIONS 150E Model Rating Voltage AMPS BT...

Page 5: ...VOLTAGE HEATER AMPS FUSE SIZE WIRE SIZE 60 C COPPER 10000W 240V 41 7A 55 A 8 100E Circuit diagram Figure 3 Warning This appliance must be grounded Warning The appliance must be connected to a 80 150E...

Page 6: ...precaution against possible electrical shock Heater circuit must be protected with proper fuses 5 The mounting structure and the anchoring hardware must be capable of supporting the weight of the heat...

Page 7: ...by columns or machinery and the air flow should wipe exposed walls rather than blowing directly on them When more than one heater is used in an area the heaters should be installed in a way that the...

Page 8: ...tion that are strong enough to hold the unit Mounting the Bracket Refer to Figures 6 1 Locate a wood stud in the wood ceiling joist If you cannot locate a wood stud you must install a wood piece on th...

Page 9: ...secure the unit once suspended at horizontal or vertical level ADJUSTING AIR FLOW DIRECTION 1 To tilt the unit vertically loosen the bracket screws see figure 7 and see figure 8 to view multiple verti...

Page 10: ...MULTIPLE VERTICAL ANGLES MOUNTING THE HEATER IN THE WALL S WOOD STUDS ONLY Figure 10 NOTE Do not place any objects on the heater...

Page 11: ...se follow the instructions below Note 1 Turn off the power to the supply line for the heater before you select the build in external thermostat Note 2 Please find the rocker switch on the back of the...

Page 12: ...or ETL standard requirements Note5 The lead wire of external temperature control external thermostat must have a minimum gauge of 16 AWG External thermostat installation 1 Pop the piece out to open th...

Page 13: ...ach wire into a circle 6 Place the twisted wires through the hole Figure 14E Figure 14F 7 Connect the wires to the heater and secure in place Figure 14G 8 Tighten back the screws with a screwdriver Fi...

Page 14: ...d in the base of the heater See Figure 16 4 Turn on the power at the main service panel NOTE All wiring must be carried out by a certified electrician and comply with national and local electrical cod...

Page 15: ...on as the Power switch The power button is also used to change the heating output between low high L H the LED will display L or H accordingly Model HA24 150E Low L 10000W High H 15000W Model HA24 100...

Page 16: ...r a while when the heater is off and the heater will makes a long beep that indicates the exit of the Matching FCC STATEMENT 1 This device complies with Part 15 of the FCC Rules Operation is subject t...

Page 17: ...off when the unit cools down back to normal levels but the reason of the overheating must be determined and corrective action taken before further operation THE HEATER MUST STOP WORKING WHEN THE CAUT...