24
((
Low-pressure protection.
- Check whether the low-pressure
sensor is broken.
- Check the refrigerant gas level.
- Check whether the water inlet and
ambient temperature values are
too low.
- Replace the low-pressure sensor.
- Call in a refrigeration engineer to
perform a sealing check on the
FLUFXLWDQGDJDVUHÀOO
5HGXFHWKHZDWHUÁRZUDWH
EE08
Communication fault.
- Check the cable and its connection.
- Reconnect the cable.
EE09
Air temperature outside of
the operating range.
The heat pump operates at between
&DQG&
- Reconnect the sensor.
- Change the sensor.
- Wait for the correct temperature.
The Aéromax Piscine emits
vibration noises.
- Condition of the vibration isolators.
- Mounting on the ground.
- Replace the isolators.
- Retighten the mountings.
- Contact your installer.
Water leak on a connector.
- Connector tightness.
+DQGWLJKWHQ
+DYHWKHFRQQHFWRUUHSODFHG
Water present under the
Aéromax Piscine.
- Check that the drainage is not
blocked, if provided.
- Check that it is not a condensate
leak (circulate the water with the
Aéromax Piscine switched off to
FRQÀUPWKDWWKHOHDNVWRSV
- Clean the drainage system.
Pool water not warm
enough.
- Check the Aéromax Piscine
operating mode.
- Check the temperature setpoint.
&KHFNWKHÀOWHUXQLWRSHUDWLQJWLPH
- Pool coverage system present.
- Switch to heating mode.
- Raise the temperature setpoint.
- Increase the time.
- Cover the pool when not in use.
Pool water too warm.
- Check the temperature setpoint.
- Lower the temperature setpoint.
6ZLWFKWR$872PRGHRU
&22/,1*PRGHZLWKDQ
appropriate setpoint.
,QVWDOODWLRQPDQXDO6HUYLFLQJDQG0DLQWHQDQFH