11
For more information about our products and how to contact us, please visit thermopatch.com
Message on display
Cause
Effect
Er1
Temperature sensor defective
Heating relais switches off
Err
Defect in the ambient temperature
sensor of the electronics
Heating relais switches off
Col
Display connection alarm
Relais switches off
Each warning signal is accompanied by a sound signal that can be silenced by pressing a button.
4.3 Automatic head rotation on or off
The automatic rotation of the press head can be switched off with a button.
This is on by default so that the press head rotates automatically after completion of the press cycle.
The button for activating or deactivating is located under the round flap on top of the press arm.
If the machine automatically opens, press the button to turn it off. If the machine does not rotate to open
automatically, press the button to turn it on.
4.2.7 Error messages
Button inside for
(de-)activating the
automatic
headswing