Alarm 01:
PT100
Inconsistent interpretation of the reading -
Probe signal lost (sensor or cable). The heating
control is instantly disabled.
Alarm 02:
Platen overheating
Temperature reading above 240° C.
The heating control is instantly disabled.
Alarm 06:
Platen lift
The top travel limit is not read during the lift
phase before the platen lift time-out ends.
Alarm 10:
Pb COM.
Communication between the power board
and the screen board interrupted.
Contact your reseller.
Alarm 13:
Temperature setpoint not reached
Rising or falling temperature triggers
or – 30° C maximum around the setpoint.
Press in the red zone to clear the fault. The work page will be displayed.
4.2.1 Error messages
List of alarms/events:
Message on display
Cause
Effect
Er1
Temperature sensor defective
Heating relais switches off
Err
Defect in the ambient temperature sensor
of the electronics
Heating relais switches off
Col
Display connection alarm
Relais switches off
Each warning signal is accompanied by a sound signal that can be silenced by pressing a button.