![Thermogroup Thermomirror EZ 12V Installation Manual Download Page 2](http://html1.mh-extra.com/html/thermogroup/thermomirror-ez-12v/thermomirror-ez-12v_installation-manual_1105675002.webp)
If you have any questions or queries regarding this product, or any other products or services
you can view our complete range online, WWW.THERMOGROUP.COM.AU
The Thermomirror 12Volt unit requires a mains supply,
12Volt Transformer (supplied) and a switch. Measure and
mark out all the necessary items before you install the
Thermomirror (Diagram 1a). If necessary, chase into the wall
to accommodate fixtures and wires.
The Thermomirror 12Volt unit should be wired into an
existing lighting circuit via the transformer (Diagram 1a) or
PIR Movement sensor.
When planning the installation, ensure a 5mm gap is present
around the perimeter of the mirror (Diagram 1b). Any contact
with hard materials could result in a breakage.
To avoid air bubbles whilst sticking the heating element,
peel off the protective paper a quarter of the way. Now line
up the mirror with the Thermomirror sticky side down.
Stick the first part down and ease the protective paper
away whilst smoothing out the Thermomirror onto the
mirror.
Remember to position the Thermomirror connection box
and power cable in the closest available position to your
connection point.
It is recommended to install insulation. We recommend
Econoboard (6106) behind Thermomirror to achieve
optimal performance and efficiency.
This Thermomirror is a 12Volt unit and is designed to go in Zone 0 or Zone 1 in the bathroom (i.e. Shower Niche). Please
note, the transformer and switches used need to be located outside of Zone 1. The transformer needs to be connected to
the mains supply in accordance with current local electrical regulations and must be installed no further than 2 metres
from the Thermomirror. The transformer can be installed in the ceiling or the wall cavity – if mounting in the wall cavity,
the transformer must be behind a switch plate to enable access. The Thermomirror must be at least 100mm smaller than
the mirror so the mirror can be glued directly to the wall. Never rely on the bond between the mirror and Thermomirror to
hold the mirror, the mirror must be glued directly to the wall. Always seal around edges of mirror with silicone when
installing in a shower niche. If the mirror has any hanger/mounting brackets, please ensure the Thermomirror is small
enough to avoid these as the Thermomirror demister pad cannot be cut or punctured.
12V Transformer
12V Thermomirror
Ensure mains supply
is RCD protected
Light
Switch
Light
Mirror
5mm Expansion Gap
Tiles