![ThermoFlow Elex 12 Installation Manual, User Manual, And Warranty Information Download Page 15](http://html1.mh-extra.com/html/thermoflow/elex-12/elex-12_installation-manual-user-manual-and-warranty-information_1105644015.webp)
Mounting instructions
Technical specifications
Instant water heater model
Electric supply
Nominal power rating
Elex 8.5
220-240V 50/60Hz
8.5 kW
Elex 12
220-240V 50/60Hz
Nominal current
Flow rate (∆t=45°F)
Flow rate (∆t=65°F)
Cable size
Temperature range
Switch on flow rate
Non-usage consumption
Protection class
Type of protection
Unit Dimensions
Unit weight
Water connections
Max. pressure water mains
Switch on flow pressure
35-39 A
1.3 GPM
0.9 GPM
10 AWG
104-140 °F
0.58 GPM
<1 Wh/h
I
IP 24
13¾ x 7⅞ x 4¾''
5.4 lb
1/2’’ NPT
115 PSI
15 PSI
50-55 A
1.8 GPM
1.3 GPM
8 AWG
104-140 °F
0.58 GPM
<1 Wh/h
I
IP 24
13¾ x 7⅞ x 4¾''
5.4 lb
1/2’’ NPT
115 PSI
15 PSI
12 kW
Commissioning
• Fill the device and vent it by opening a hot water tap connected to it.
• Only switch on the electrical supply once the device is clear of any
air.
• Check the operation of the device.
Frost
This device should be installed in a climate-controlled location,
protected from freezing temperatures.
15
Electric tankless Water heater - Installation Maunal and User Guide
TM
Circuit Breaker
2-POLE 40A