This device does not require any maintenance by the user.
Repairs should always be carried out by a
licensed contractor.
A service inspection should be performed every year. Descaling of the device during this inspection is highly
recommended, especially if you live in an area with hard water. Higher termperature water will intensify
calcification. It is therefore recommended to set the device at a maximum of 131°F in areas with extremely
hard water.
Clean the unit housing with a damp cloth. Do not use harsh chemicals or abrasives.
After extended vacation or non-use device should be run at maximum temperature (tap at minimum flow)
before reusing. Pipes should be flushed for one minute.
The magnesium anode protects the tank against corrosion. This is a cathodic process, during which the
anode slowly dissolves. The anode should therefore be inspected and replaced if necessary , by a licensed
plumber every two years.
Check the drain for blockages. If blocked, unblock the drain or call a licensed contractor.
MAINTENANCE
Description
Mounting
Wall Mounting
Operating Ressure
Temperature Range
Nominal Voltage
Nominal Volume
Frequency
Nominal Capacity
2.6 Gallon Water Heater
Under-sink
Vertical
90 PSI
45-165
o
F
110-120 V
1500 W
2.6 Gallons
Maximum Recommended Volume
2.6 GPM
Water Connection
1/2” NPT
60 Hz
TECHNICAL SPECIFICATIONS