This device does not require any maintenance by the user. 

Repairs should always be carried out by a 

licensed contractor.

A service inspection should be performed every year. Descaling of the device during this inspection is highly 

recommended, especially if you live in an area with hard water. Higher termperature water will intensify 

calcification. It is therefore recommended to set the device at a maximum of 131°F in areas with extremely 

hard water.

Clean the  unit housing with a damp cloth. Do not use harsh chemicals or abrasives.

After extended vacation or non-use device should be run at maximum temperature (tap at minimum flow) 

before reusing. Pipes should be flushed for one minute.

The magnesium anode protects the tank against corrosion. This is a cathodic process, during which the 

anode slowly dissolves. The anode should therefore be inspected and replaced if necessary , by a licensed 

plumber every two years.

Check the drain for blockages. If blocked, unblock the drain or call a licensed contractor.

MAINTENANCE

Description
Mounting
Wall Mounting

Operating Ressure

Temperature Range

Nominal Voltage

Nominal Volume

Frequency

Nominal Capacity

2.6 Gallon Water Heater
Under-sink
Vertical

90 PSI

45-165

F

110-120 V

1500 W

2.6 Gallons

Maximum Recommended Volume

2.6 GPM

Water Connection

1/2” NPT

60 Hz