![ThermoFisher Scientific HERASAFE 2030i Series Operating Instructions Manual Download Page 62](http://html1.mh-extra.com/html/thermofisher-scientific/herasafe-2030i-series/herasafe-2030i-series_operating-instructions-manual_1105593062.webp)
| Operation
52
|
50155215
Herasafe 2030i / Maxisafe 2030i
Chapter 6
Standby mode is entered when you close the window from within a working session,
which is indicated by the closed window in the side-view symbol graphic. A Standby
header appears to the right of the graphic, showing the unit is in standby mode,
maintaining cleanliness and containment, and ready to resume work when you move the
window back to the working position. The green checkmark next to the Standby header
signifies that everything is working properly.
In the Control Panel Area, buttons are highlighted to indicate that functions are still on,
including the sample chamber illumination, the fans, and the power receptacles. The
“AutoStop” button
is also available because the unit is running.
If the window is closed, the fans will switch to reduced flow, as indicated by the small blue
circle with the “1/2” label
.
Cleaning and Loading Mode
Cleaning mode is entered when you fully open the front window using the hinge for
accessing the sample chamber, for example, in order to decontaminate or introduce larger
accessories. Cleaning mode is indicated by the flipped-up window in the side-view symbol
graphic and the “Cleaning mode” header that appears next to it, as shown in Figure 37.
Additional text like “SmartClean Plus” and “Sample chamber open for cleaning and/or
loading or unloading.” further explains what cleaning mode is for.
The “Health Status” Icon in the Info & Health Status Area is a yellow alert triangle.
Figure 37
Main Screen - Unit cleaning
Summary of Contents for HERASAFE 2030i Series
Page 1: ...Valid 30 08 2017 50155204 21st September 2021 Safety cabinets 50155215 Rev B...
Page 6: ...Table of Contents 4 50155215 Herasafe 2030i Maxisafe 2030i...
Page 10: ...Figures 4 50155215 Herasafe 2030i Maxisafe 2030i...
Page 20: ...Delivery 10 50155215 Herasafe 2030i Maxisafe 2030i Chapter 2...
Page 130: ...Operation 120 50155215 Herasafe 2030i Maxisafe 2030i Chapter 6...
Page 134: ...Preparation 124 50155215 Herasafe 2030i Maxisafe 2030i Chapter 7...
Page 136: ...Shut down 126 50155215 Herasafe 2030i Maxisafe 2030i Chapter 8...
Page 144: ...Maintenance 134 50155215 Herasafe 2030i Maxisafe 2030i Chapter 10...
Page 154: ...Technical Data 144 50155215 Herasafe 2030i Maxisafe 2030i Chapter 12...
Page 156: ...Device Log 146 50155215 Herasafe 2030i Maxisafe 2030i Chapter 13...
Page 157: ...Herasafe 2030i Maxisafe 2030i 50155215 147 Certificate of Decontamination...
Page 158: ...Certificate of Decontamination 148 50155215 Herasafe 2030i Maxisafe 2030i Chapter 14...
Page 173: ...Herasafe 2030i Maxisafe 2030i 50155215 163 Appendix City Time Zones Chapter 15...