Installation Instructions
Ensure all minimum clearance requirements are met and the materi-
als used are compliant to your local building codes.
Before installing the flush mount enclosure, ensure the site to be
fixed is fully prepared with the hole cut the correct size and the
mounting points securely in place.
STEP 1:
Attach the brackets to the rear
of the heater. The dimensions
for the spacing of the brackets
is listed in the table.
MODEL
“
D
”
DISTANCE FROM END
TO BRACKET (mm)
THX2400 &
THX2400DC
170
THX3600 &
THX3600DC
288
STEP 2:
Screw the enclosure into the
battens.
NOTE: screws are not included
.
STEP 3:
If there is no roof access,
connect the heater to the power
source, ensure the power is OFF
.
STEP 4:
Lift the heater into the enclosure
ensuring the brackets are to the
side of the mounts
STEP 5:
Push the heater to the left en-
suring the brackets engage in
the mounts. It will then drop in.
Shake the heater to ensure that
it is securely mounted.