background image

 

 

 

Installation Instructions

 

 

Ensure all minimum clearance requirements are met and the materi-
als used are compliant to your local building codes. 

 

 

Before installing the flush mount enclosure, ensure the site to be 
fixed is fully prepared with the hole cut the correct size and the 
mounting points securely in place.

 

 

 

 

STEP 1: 

 

Attach the brackets to the rear 
of the heater. The dimensions 
for the spacing of the brackets 
is listed in the table.

 

 

MODEL

 

D

 

DISTANCE FROM END 

TO BRACKET (mm)

 

THX2400 & 

THX2400DC

 

170

 

THX3600 & 

THX3600DC

 

288

 

STEP 2: 

 

Screw the enclosure into the 
battens. 

 

NOTE: screws are not included

.

 

 

STEP 3: 

 

If there is no roof access, 

 

connect the heater to the power 
source, ensure the power is OFF

.

 

 

STEP 4: 

 

Lift the heater into the enclosure 
ensuring the brackets are to the 
side of the mounts

 

 

STEP 5: 

 

Push the heater to the left en-
suring the brackets engage in 
the mounts. It will then drop in. 
Shake the heater to ensure that 
it is securely mounted.

 

Summary of Contents for HEATSTRIP Max THX2400DC

Page 1: ...OPERATION INSTALLATION AND MAINTENANCE MANUAL THX THX DC Flush Mount Enclosure Take heating to the Max...

Page 2: ...to beams or poles mounted end to end or 2 units together Refer to the following pages for more detailed information on each mounting option CEILING TWIN MOUNT BRACKET STANDARD BRACKET EXTENSION MOUNT...

Page 3: ...r environment Maxi mum mounting heights should be strictly followed otherwise the performance of the units may be reduced The facia of the enclosure is manufactured from 316 Stainless Steel and the re...

Page 4: ...sure dimensions PART No MODEL A mm B mm C mm THXAC 030 THX2400 995 940 935 THXAC 031 THX3600 1320 1265 1260 THXAC 030 THX2400DC 995 940 935 THXAC 033 THX3600DC 1207 40 1162 40 1157 40 View from top Vi...

Page 5: ...diagrams below are the minimum clearance required for the installation of the Flush Mount En closure It is imperative that all cables backing materials insulation and other materials are keep clear of...

Page 6: ...dimensions for the spacing of the brackets is listed in the table MODEL D DISTANCE FROM END TO BRACKET mm THX2400 THX2400DC 170 THX3600 THX3600DC 288 STEP 2 Screw the enclosure into the battens NOTE s...

Page 7: ...urable materials however regular care and maintenance of your product will help prolong its life It is recommended that you wipe down your Flush Mount Enclosure and with a soft cloth gently wipe the s...

Page 8: ...f an examination of the faulty product or compo nents by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidenta...