5
3.1 Installation instructions
The Bliss Euro is an electric heater designed to be mounted on the wall or freestanding using the supplied
castor wheel set. These units are suitable for heating enclosed indoor rooms such as bedrooms, studies,
offices, living areas and bathrooms.
ATTENTION!
For hard wired installations, electrical connection and first operation of this appliance should be
carried out by a qualified installer.
Installation Location
The Bliss Euro should be installed according to normal trade prac-
tice and in compliance with legislation in relevant country.
The panel convector is
CLASS I
and is protected against
splashed water (IP24). Therefore it can be installed outside
the shaded area shown in the bathroom area.
(See right hand side diagram)
Ensure the safety zones (mm) in diagram
(right hand side)
are kept free.
If the wall covering is laid on foam, a spacer the same thickness as
the foam must be placed under the panel heater’s support. This
ensures there is free space behind the panel heater to make sure its
control settings are not adversely affected.
The Bliss Euro must not be installed immediately below a wall
socket. The heater must be connected to a socket outlet or perma-
nent terminal box at least 10cm to one side of the heater. If the
heater is installed in the Bathroom or in humid area, the socket
outlet or permanent terminal box must conform to the IP24 re-
quirement. If installed in the bathroom, ensure the socket is at least
25cm above the floor level.
The Bliss Euro must not be installed in a draught likely to affect the
control settings (under a ventilating fan, etc.)
3.2 Wall Mounting Bracket
The wall mounting bracket is oriented centrally (See RHS diagram).
256mm
158mm
Width
Model
Width
BE1000
214mm
BE1500
347mm
BE2000
347mm
BE2400
606mm
120mm MINIMUM NON BATHROOM
APPLICATION
(250mm IF USED IN A BATHROOM)
HOLE CENTRES