GUARANTEE CONDITIONS  
 

1.     All appliances are supplied under a guarantee against material and manufacturing errors. The guarantee is limited to a maximum of the supply of a replacement com-
        ponent and only applies if the instructions for installation and use enclosed with the appliance have been followed, and if the product is being used under normal con-
        ditions in the dealer’s assessment. 
2.     There is a five year guarantee on fire refractory clay, with effect from the date of purchase. Shrinkage cracks and discolouration after heating are not covered by the  
        guarantee. 
3.    There is a five-year guarantee on cast iron fires, cast iron stoves and cast iron recessed fires. A two-year guarantee is given on components of these appliances, such  
        as ceramic sealants, nuts, bolts, screws, washers, mastic, knob springs, bearings, fans, fireguards and sheet metal parts. 
4.    There is a two-year guarantee on gas appliances, with the exception of thermocouples and fuses. The appliance must have been installed by a registered installer in    
        compliance with current standards. 
5.    The guarantee conditions only apply if the attached guarantee card is completely filled in on the date of purchase and returned to the importer within 10 days. This is 
        also the date of in ception of the guarantee. 
6.    The guarantee lapses if changes have been made to the appliance without the advance knowledge and written permission of BosNed, and when an appliance has been 
        shipped without sound packaging and transport protection. 
7.    The following are not covered by the guarantee: 
    -   Defects caused by inexpert assembly and/or treatment. 
    -   Costs of transport, assembly and dismantling. 
    -   Glazing, fire gratings, refractory stones, flue gas baffle plates, heat shields and controllers. 
    -   Paint discolouration which may develop after heating. 
    -   Overheated parts due to faulty installation and/or fitting. 
8.    In v iew of the tremendous variations in the possible options for building a chimney, we are unable to give any guarantee regarding t he draught of a chimney that        
        might lead to complaints about smoke. The chimney must be built by a professional and this establishes the guarantee for the proper functioning of this appliance. 
9.    The dealer/importer will supply a new component free of charge for every component that becomes defective during the guarantee period. The dealer must return the 
        defective component to the importer, stating date of purchase, type of appliance and serial number. 
10.   Renewal or replacement of components that fall under the guarantee cannot prolong the total length of the guarantee. The guarantee provides no right whatsoever to  
        indemnification in the event it is not possible to use the fire. 
11.   Liability can never be accepted for loss in any form whatsoever sustained by the customer, third parties or their property and caused directly or indirectly by the  
        product. 
12.   Complaints will only be dealt with if the customer has met all his obligations, including his obligation to pay. 
13.   For further provisio ns, please refer to our Metaalunie and Orgalime conditions, which are filed at the office of the Court in Rotterdam (the Netherlands). 

Send the guarantee card to your dealer / importer in a 
properly stamped envelope 

 

 

 

 

 

 

 

 

 

Address;

 

 

Postcode ;

 

 

Town/city ;

 

G U A R A N T E E  C A R D 

Summary of Contents for Rose 6

Page 1: ...Page 1 ROSE Classic Operating and installation instructions ...

Page 2: ... burner Page 4 2 3 Handcontrolled burner 2 4 Turning off the stove 2 5 Maintenance 3 Downdraught cutout 4 Installation instructions Page 5 4 1 General 4 2 Preparations for installing the stove 4 3 Installing the stove 4 4 Fitting the decorative coal effect Page 6 4 5 Thermostat probe 5 Technical data Page 7 6 Illustrations Page 8 till 10 Subject to alterations 0 20022006 ...

Page 3: ...3 1 x Operating and Installation instructions 1 x Guarantee card 2 Operation instructions Rose See page 9 The Rose has two burners The rear burner is controlled by the thermostat you select the setting and the modulating thermostatic control maintains the correct temperature The front burner is controlled manu ally you select the setting and the burner continues to operate at that setting until yo...

Page 4: ...h If a liquid is spilt on the stove it should be turned off immediately and once it has cooled down any marks should be removed with a mild soap solution Abrasive cleaners must not be used It is advisable to have the stove and flue checked and cleaned by a qualified installer before each heat ing season If the special glass panel is broken or cracked have it replaced before you use the stove again...

Page 5: ...ofed or is fitted with an extractor fan suitable apertures must be provided to equalise the pres sure between inside and outside so that the operation of the flue is not affected by low pressure in the room When installing gasstoves we advise in general to connect the stove to a full stainless steel or aluminium chimney liner 100 mm This to avoid possible problems with the downdraught cutoutsystem...

Page 6: ...s on to the rear mounting plate which is about 8 cm above the burner unit Close the door and fix the two screws Important always take care that the door is fixed tight before op erating the stove Now light the stove according to the Operating Instructions 4 5 Thermostat probe The stove is supplied with a remote mounting thermostat capaillary probe The probe should be placed in a position which wil...

Page 7: ...Page 7 5 TECHNICAL DATA 1 Screws 2 Doorknob 3 Glass door 4 Lower ash pan door 1 4 3 2 Situation of ceramic coal sets ...

Page 8: ...Page 8 GASCONNECTION ...

Page 9: ...Page 9 ...

Page 10: ...I3 Rose 9 NAT GAS I2H Rose 9 LPG I3 Pre pressure Mbar 20 37 20 37 Burner pressure Mbar 6 3 26 0 10 6 26 0 Nominal input Kw Hi 7 5 8 3 10 9 8 3 Nominal output kW 6 2 7 1 9 2 7 2 Flue connection φ mm 100 100 100 100 Gas connection 3 8 G 3 8 G 3 8 G 3 8 G ...

Page 11: ...nce is fitted with insulated covering one of the following materials should only be used Loose white insulation wool heat resistant to 1000 C Rocktherm 180 012 insulation wool 700 C from Rockwool or the equivalent Other mineral insulation wool without binding agents synthetic resins or water repellent substances mineral oils Wait at least 6 weeks before firing a newly bricked chimney or after reno...

Page 12: ...by the guarantee Defects caused by inexpert assembly and or treatment Costs of transport assembly and dismantling Glazing fire gratings refractory stones flue gas baffle plates heat shields and controllers Paint discolouration which may develop after heating Overheated parts due to faulty installation and or fitting 8 In view of the tremendous variations in the possible options for building a chim...

Reviews: