6 INSTALLATION
A: view A-A, seen from the inside
B: cam
CEE plug - 3P +
32 A
A: view A-A, seen from the inside
B: cam
CEE plug - 3P + N +
32 A
1
Check whether the mains voltage
is 400 V 3~ +
50 Hz.
If not, do not connect the electric heater.
2
If the electric heater has not been
provided with a power plug, mount this
following the instruction below:
- Disassemble the plug. Loosen the
screws of the terminals and the pull
relief. If necessary, cut the tulle to size.
- Slide the housing over the cable.
- Cut the cores (if necessary) to the
correct length for the terminals and
mount the cores as follows:
-
green/yellow = earth wire
(most important wire)
L1 or R1
L2 or S2
L3 or T3
brown
black
blue
N
Do NOT use
(with 3P+N+
)
In this case blue can be used as phase.
See NEN 1010 chapter 51, art. 514.3.4.
Exchanging the colours brown, black and
blue will not affect the operation of the
electric heater.
3
Securely tighten the screws of the
terminals and, subsequently, of the pull
relief. Place the housing on the interior
work and screw it on.
4
Before connecting the electric heater to
the power socket, set the switches 3+4+5
to position 0 (off). See Use and operation,
chapter 7.
5
Set the switch to the required position.
See Use and operation, chapter 7.
If you use an extension cable,
pay attention to the advised
voltage loss of the extension
cable of 10 V. See the table
below.
4 mm²
50 m
26 A
9 V
6 mm²
100 m
26 A
12.5 V
Fully unwind cable reels, if used.