9 [EN] 

10. ELECTRICAL CONNECTIONS

This dehumidifier was designed to operate in a 230V~50Hz electrical installation. Make sure that the electric sockets 
are connected to earth and that all safety precautions are taken. 

11. OPERATING CONDITIONS

This dehumidifier can be operated within an ambient temperature range from +3 to +35°C and with a relative humidity 
from 35% to 90%. It is suitable for application on construction sites, residential buildings,  museums, archives, garages 
and storage rooms. 

12. SPECIFICATIONS

Model 

ProDry TD

 

4

5 Dual

ProDry 

TD

 

8

0 Dual

Temperature Range 

+3 °C / +32 °C

Relative Humidity Range 

50% - 90% 

Defrosting System 

Hot gas 

Rated Voltage 

115/230 

V

~50 

Hz

 

Rated Power 

32°C – 80% 

1,0 

kW

 

1,2 

kW

 

Refrigerant 

R410a 

Drying Capacity 

(l/24H) 

20ºC – 60% 

18 

29 

27ºC – 80% 

37 

56 

32ºC – 80% 

44 

79 

Dehumidifier 
Dimensions 

W x D x H [

mm

525 x 545 x 895 

560 x 545 x 965 

Weight 

41 

kg

 

52 

kg

 

Time Counter 

 

 

Electronic Control 

 

 

Summary of Contents for ProDry TD 45 Dual

Page 1: ...INSTRUCTION MANUAL EN ProDry TD 45 Dual ProDry TD 80 Dual ...

Page 2: ...2 EN ...

Page 3: ... AND TRANSPORTATION 5 5 OPERATING INSTRUCTIONS 6 6 ELECTRONIC CONTROLS 7 7 CONDENSATE OUTLET 8 8 AUTOMATIC DEFROSTING SYSTEM 8 9 CONDENSATES PUMP WORKING MODE OPTION 8 10 ELECTRICAL CONNECTIONS 9 11 OPERATING CONDITIONS 9 12 SPECIFICATIONS 9 13 TROUBLESHOOTING 10 14 MAINTENANCE 10 15 ELECTRIC DIAGRAMS 11 ...

Page 4: ...r a strong counter so that the dehumidifier cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electrical wiring or components become wet thoroughly dry them before using the unit If in doubt do not use the dehumidifier and consult reseller or authorized work...

Page 5: ... with outside any sources of moisture and the room temperature can all either speed up or slow down the dehumidification process The dehumidifier functions according to the condensation principle with heat recovery The fan takes the humid air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a conden...

Page 6: ...water tank is in position If working with a remote hygrostat set the required humidity value on it see point 9 Switch on the I 0 switch and check if time counter is running Both I 0 switch and the time counter are located in the upper right side of the dehumidifier along with the leds see point 6 The control panel must be illuminated after switching on the I 0 switch Check for the proper operation...

Page 7: ... unit is in automatic defrost mode this is not an error or a fault See page 8 7 Internal high temperature The air filter is blocked Check and clean the air filter 8 Water tank The water tank is full and must be emptied See page 8 9 Set point The relative humidity set point has been reached See above 10 Ambient temperature Turns off the dehumidifier when limit temperatures are reached 1 Voltage set...

Page 8: ...f the evaporator It transmits an electrical signal to the main electronic board It has been designed to avoid frequent defrost cycles and consequent loss of efficiency The relay switches off the fan and simultaneously opens the solenoid valve Hot gas is guided into the evaporator until the latter is completely free of ice Subsequently the dehumidifier will operate again in its normal mode when the...

Page 9: ...idity from 35 to 90 It is suitable for application on construction sites residential buildings museums archives garages and storage rooms 12 SPECIFICATIONS Model ProDry TD 45 Dual ProDry TD 80 Dual Temperature Range 3 C 32 C Relative Humidity Range 50 90 Defrosting System Hot gas Rated Voltage 115 230 V 50 Hz Rated Power 32 C 80 1 0 kW 1 2 kW Refrigerant R410a Drying Capacity l 24H 20ºC 60 18 29 2...

Page 10: ...urce The fan is out of operation The dehumidifier is running a defrost cycle The dehumidifier will switch on the fan automatically after some minutes If not consult reseller or authorized workshop Fan not running Consult reseller or authorized workshop Unit continuously in defrost and you can see an ice block on the evaporator Defective control assembly Consult reseller or authorized workshop The ...

Page 11: ...11 EN 15 ELECTRIC DIAGRAMS DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING OPTION ...