AGA 45 / 75
40.020.948 - rev.
05 - 2017
17
English
4.2
Switching off
1. Switch the selector switch to 0.
2. Close the shut-off valve on the gas
supply.
5
MAINTENANCE
5.1
Maintenance table
Use the table in this manual to record the
maintenance after each winter season.
/i
Hot
Do not touch the outlet or combustion
chamber!
Do not start maintenance until they
have cooled down.
Description
Period
Weekly Monthly Every six
months
Annually
Remove dust and deposits from the heater.
X
Check the heater (in a clean environment).
Dealer
Check the heater (in a dusty environment).
X
Check and clean the suction inlet for the combus-
tion air.
X
Check and clean the inlet grid.
X
Check the hot air fan for operation and damage.
X
Check the heater for correct combustion. The
flame must be blue. If the flame is yellow, consult
the dealer.
X
Clean the ionisation electrode with steel wool.
X
Check the adjustment of the ionisation electrode
and adjust as necessary, see “Adjusting the ionisa-
tion electrode”.
X
Check the heater's wiring.
X
Summary of Contents for AGA 45
Page 3: ...AGA 45 75 40 020 948 rev 05 2017 3 i 6 7 8 9 10 11 A B A C B D A 5 0 5 A...
Page 46: ...46 40 020 948 rev 05 2017 AGA 45 75 P 47 48 49 50 51 52 54 54 55 E 55 1 A B C D E F G H I J K...
Page 47: ...AGA 45 75 40 020 948 rev 05 2017 47 p 1 1 1 1 2 2 A B C 1 3 1 4 3...
Page 51: ...AGA 45 75 40 020 948 rev 05 2017 51 p 5 5 1 i X X X X X X X X X...
Page 52: ...52 40 020 948 rev 05 2017 AGA 45 75 P 5 2 1 2 3 5 3 1 2 10 3 6 6 1 i 1 2 3 4 5...
Page 53: ...AGA 45 75 40 020 948 rev 05 2017 53 p 7 8 9 10 11 12...
Page 54: ...54 40 020 948 rev 05 2017 AGA 45 75 P 7 8 13 10 14 11 15 16...