GENERAL SAFETY INFORMATION
: This heater requires hardwire installation (no plug). The installation of this
product must be carried out by a certified electrician in accordance with all applicable local
and national electrical codes.
NOTE: Compatible with a 240V line voltage single pole wall thermostat. This thermostat
must be installed by a certified electrician.
Read and understand all installation and operation
instructions prior to operating this unit. Observe all safety instructions.
1. Use only copper wires rated for at least 60ºC.
2. Heater air flow must be directed parallel to or away from adjacent wall.
3. Observe wall, floor and ceiling clearance requirements.
4. All wiring must be done according to applicable national and local electrical codes in the
United States and Canada. The heater must be grounded as a precaution against possible
electrical shock. Heater circuit must be protected with proper fuses.
5. The mounting and anchoring hardware must be capable of reliably supporting the
weight of the heater and its mounting bracket.
6. All electrical power must be disconnected and the main service box must be locked
before inspecting cleaning or servicing the hater. This precaution must be followed to
prevent serious electric shock.
7. This heater is not suitable for use in hazardous locations as defined by the national fire
protection association (NFPA) in the United States. This heater has hot and arcing
sparking parts inside. Do not use it in areas where gasoline paint or flammable liquids
are used or stored.
8. This heater is not suitable for use in corrosive atmospheres such as marine
greenhouses or chemical storage areas.
9. This heater must be mounted at least 8 feet (2.44 m) above the floor.
Improper installation or failure to follow the procedures outlined in this
instruction manual can result in serious electrical shock.