Pump Flow Diagram
Supply Return
Pump
Strainer (PD Pumps Only)
Relief Valve
(PD Pumps Only)
Pressure Gauge
(PD Pumps Only)
Reservoir
CFT-300 Fuses
Three Class J fuses are used to protect the motor, in addition to a thermal
overload device. These fuses are located inside the main control panel. In the
event of an open fuse, investigate and correct the source of the overload before
replacing the fuse(s).
Always turn off the unit and disconnect the line cord from the power
source before attempting to do any service.
To replace the fuses, remove the two screws from the main control panel and
then open the panel door. For units equipped with a 380V, 3-Phase, CP-55
pump, our part number 008596, replace the fuses with Class J, 600V, 3A,
TDLY fuses only. Do not replace the fuses with an alternate amperage.